What steps will reproduce the problem?
1. reload ajax on data table more than one time
What is the expected output? What do you see instead?
Expected: select dropdown should update with new table data
Actual: Select dropdown contains the values from the first ajax load
What version of the product are you using? On what operating system?
columnFilter 1.5.1, Windows 7
Please provide any additional information below.
I was able to correct this by modifying line 397, which is in the
fnCreateSelect function, by changing the line:
if (oSettings.iDraw == 2 && oSettings.sAjaxSource != null &&
oSettings.sAjaxSource != "" && !oSettings.oFeatures.bServerSide) {
to:
if (oSettings.iDraw >= 2 && oSettings.sAjaxSource != null &&
oSettings.sAjaxSource != "" && !oSettings.oFeatures.bServerSide) {
Each reload increments the iDraw counter by one, so after the first refresh, it
would not update the dropdown any longer. Changing oSettings.iDraw == 2 to
oSetting.iDraw >= 2 fixes that issue.
Original issue reported on code.google.com by tanner.c...@gmail.com on 25 Sep 2013 at 2:14
Original issue reported on code.google.com by
tanner.c...@gmail.com
on 25 Sep 2013 at 2:14