The app does not sync any of the data elements for "0.05ml Syringes x 1" in the Vaccine Commodity Group #228

Open chai-lmis opened 9 years ago

zhuao commented 8 years ago

This issue should be caused by configuration in server. I found that all data elements related to '0.05ml Syringes' is not set to be available. they are still 'selected' status.

Please refer to server page to check this configuration. This configuration page is at Apps -> Data Administration->Data Element Group Editor

zhuao commented 8 years ago

Since the commodity "0.05ml Syringes x 1" belong to the category "PHC Facility commodities" which should not be available on tablet.

chai-lmis commented 8 years ago

created a data element group and included in the "Vaccines" group set on QA. Data element syncs on tablet now, testing to check it does not affect the scripts

chai-lmis commented 8 years ago

Fixed on the server, however app must be uninstalled and re-installed to pick up the change on the server