clintonhealthaccess / chailmis-android

Android Tablet Application for Logistics Management in the DHIS2 Platform
Other
7 stars 6 forks source link

The commodity 0.05ml syringe x 1 ( which has now been updated on the server) doesnt display when "Received" , "Adjustment", "Reports" activities are selected #246

Open chai-lmis opened 8 years ago

garymabin commented 8 years ago

Can not reproduce under QA env.

chai-lmis commented 8 years ago

it happens on QA and Dev. Select Receive activity -> Vaccines-> 0.05ml syringe is not shown in the list of commodities

chai-lmis commented 8 years ago

the 0.05ml syringe does not appear in "Received" and Vaccine report - "Monthly Health Facility Devices/Other Materials Utilization Report"

garymabin commented 8 years ago

the 0.05ml syringe's isVaccine flag is not correctly set in the server data, please check it

chai-lmis commented 8 years ago

vaccine flag is now set on the server, app needs to be re-installed to pick it up