columncolab / EMC2

Earth Model Column Collabratory
BSD 3-Clause "New" or "Revised" License
10 stars 7 forks source link

sigma_d_tot is 0 in some cases where it shouldn't #28

Closed isilber closed 3 years ago

isilber commented 3 years ago

In the case I examined, the pl fields all have '0' values (no precipitating ice class) but the other fields are filled with other finite values. While sigma_d for each hydrometer type (except for pl) has various values, sigma_d_tot == 0, which is obviously wrong. The problem in this case definitely revolves around sigma_d_numer_tot, which is consistently == 0, although it definitely shouldn't.