Reported by Mike that nucleation causes a hangup in coagulation when default weighting is used (nummass_source).
I tried nucleation with various weighting types and it appears to only occur for nummass_source. Code runs for flat, flat_source, nummass. Appears to hang up with coagulation of the mass mode.
Reported by Mike that nucleation causes a hangup in coagulation when default weighting is used (
nummass_source
).I tried nucleation with various weighting types and it appears to only occur for
nummass_source
. Code runs forflat
,flat_source
,nummass
. Appears to hang up with coagulation of the mass mode.