courtois-neuromod / mariostars

0 stars 0 forks source link

[SCAN] sub-05_ses-001 #38

Open me-pic opened 1 year ago

me-pic commented 1 year ago

Setup

general notes

Set-up of the physiological signals: We had some difficulties with the quality of the ECG signal during the set-up (saturated signal). We moved one electrode that was too low, and it really helped the signal quality; we had nice QRS complex after that change. PPG signal was good during set-up. The EDA values were low (around 1 microsiemens); the gain was changed to 5.

task-mariostars_run-01 completion

task-mariostars_run-01 issues

physio signal quality issue

task-mariostars_run-01 notes

During the eye tracker calibration: we could see small but constant QRS complex in the ECG signal; PPG was ok.

During the run: flat PPG signal; lot of noise in the ECG data; EDA values around 3 microsiemens. A lot of plateau artefacts in the EDA signal.

task-mariostars_run-02 completion

task-mariostars_run-02 issues

physio signal quality issue

task-mariostars_run-02 notes

During the eye tracker calibration: PPG looked ok; small but visible QRS complex in the ECG signal; EDA looked stable.

During the run: at the beginning, PPG looked ok, but flatten towards the second half of the run; noise in the ECG data, but R peaks still seemed visible. Plateau artefacts in the EDA signal.

Participant had their eyes closed for the last bull's eyes fixation

task-mariostars_run-03 completion

task-mariostars_run-03 issues

No response

task-mariostars_run-03 notes

During eye calibration: PPG looked ok; some noise in the ECG data, but small QRS complex visible; EDA noisy

During the run: saturated ECG waveform for a good portion of the run, otherwise visible R peaks in the signal; flat PPG waveform; plateau artefacts in the EDA signal

task-mariostars_run-04 completion

task-mariostars_run-04 issues

physio signal quality issue

task-mariostars_run-04 notes

During the eye tracker calibration: quality of the ECG unstable; PPG looked ok; plateau artefacts in the EDA signal

During the run: flat PPG signal; plateau in the EDA signal; saturation of the ECG sometimes; otherwise R peaks speed visible

task-mariostars_run-05 completion

task-mariostars_run-05 issues

No response

task-mariostars_run-05 notes

No response