Using bin compiled from IRMQTTServer
Why did you ignore the issue template? What are you sending to the AC when this happens? And what does the original remote send when you are trying to do the same action?
You will have to collect this data. With the information provided so far we can't even guess what you are doing and what is happening.
The remote control only controls the air conditioning on, there is nothing extra
With this issue, what is your expected actions from this library? Taking in to consideration that we don't know how to reproduce the issue you are seeing.
@hassbian-ABC I'm sorry if this comes across as snappy or terse. It's not meant to be. You are going to need to provide more information before we can help you. A LOT more information. If you don't, I dont want to, but I'm inclined to close this issue if you don't.
e.g. Have you turned on DEBUG and looked at the serial output?
You haven't even listed what version of the library and IRMQTTServer you're using. Nor the mode the A/C Remote was trying to send, what the state of IRMQTTServer was in prior (and after) and what on earth "it becomes uncontrollable" actually & effectively means.
We are NOT mind-readers. You are our eyes and ears. We can only work on what you tell us. Telling us "A Coolix remote breaks something" doesn't tell us much at all.
After receiving the infrared code, Coolix will reset the sensorTemperature to 0.00, which will become uncontrollable
If the sensorTemperature is reset to kNoTempValue, everything becomes normal
Can you please supply the sequence of messages that the actual remote is sending? e.g.
Using IRrecvDumpV3
example code to capture the actual IR messages.
Okay, I will finish it in my free time
I've reviewed the relevant code in the library, and nothing jumps out at me. Thus, I'm going to need the actual message (The Coolix 24-bit message code/number) to look any further into this.
Is IRrecvDumpV2 okay? @crankyoldgit
Is IRrecvDumpV2 okay? @crankyoldgit
Yes.
821
Not relevant as we need to know the message that YOUR remote is generating, and with the current version of the library.
新建 文本文档.txt use IRremoteESP8266-2.8.5
IRrecvDump is now running and waiting for IR input on Pin 13 Timestamp : 000005.708 Library : v2.8.5
Protocol : COOLIX Code : 0xB21FD8 (24 Bits) Mesg Desc.: Power: On, Mode: 2 (Auto), Fan: 0 (Auto0), Temp: 26C, Zone Follow: Off, Sensor Temp: Off uint16_t rawData[199] = {4398, 4440, 482, 1702, 484, 594, 482, 1700, 480, 1702, 482, 596, 482, 596, 480, 1702, 482, 596, 482, 596, 480, 1702, 530, 548, 478, 600, 478, 1704, 502, 1680, 482, 596, 476, 1706, 482, 596, 482, 596, 478, 600, 478, 1704, 482, 1700, 480, 1704, 478, 1704, 482, 1700, 482, 1700, 500, 1682, 504, 1678, 528, 550, 482, 596, 480, 596, 480, 598, 482, 596, 478, 1704, 474, 1708, 478, 600, 476, 1706, 482, 1700, 480, 598, 478, 598, 480, 598, 482, 596, 476, 602, 478, 1704, 498, 580, 476, 600, 500, 1684, 498, 1684, 480, 1704, 504, 5254, 4398, 4442, 478, 1704, 480, 596, 480, 1702, 480, 1702, 480, 598, 480, 596, 478, 1704, 478, 600, 506, 572, 490, 1692, 480, 596, 478, 600, 504, 1678, 478, 1704, 504, 574, 502, 1680, 482, 596, 502, 576, 502, 576, 480, 1702, 480, 1704, 478, 1704, 478, 1706, 478, 1704, 480, 1702, 476, 1706, 498, 1684, 476, 602, 480, 598, 500, 576, 480, 596, 502, 576, 476, 1706, 500, 1684, 506, 572, 476, 1706, 502, 1680, 494, 584, 478, 600, 478, 598, 502, 574, 504, 574, 498, 1684, 482, 596, 482, 596, 478, 1704, 476, 1706, 500, 1682, 476}; // COOLIX B21FD8 uint64_t data = 0xB21FD8;
Timestamp : 000025.956 Library : v2.8.5
Protocol : COOLIX Code : 0xB21F98 (24 Bits) Mesg Desc.: Power: On, Mode: 2 (Auto), Fan: 0 (Auto0), Temp: 27C, Zone Follow: Off, Sensor Temp: Off uint16_t rawData[199] = {4394, 4446, 480, 1704, 478, 600, 476, 1706, 474, 1708, 480, 598, 478, 600, 502, 1680, 478, 598, 480, 598, 500, 1682, 502, 576, 476, 602, 474, 1708, 488, 1694, 478, 600, 498, 1684, 478, 600, 498, 578, 476, 602, 478, 1702, 480, 1702, 476, 1706, 474, 1708, 476, 1706, 476, 1706, 474, 1708, 474, 1708, 474, 604, 478, 600, 474, 602, 506, 572, 478, 598, 480, 1700, 502, 576, 480, 598, 478, 1704, 480, 1704, 476, 602, 476, 602, 480, 598, 500, 576, 480, 1702, 482, 1700, 478, 600, 500, 578, 476, 1708, 504, 1678, 500, 1684, 476, 5282, 4394, 4442, 498, 1684, 476, 602, 502, 1680, 478, 1704, 504, 574, 480, 596, 480, 1702, 476, 602, 500, 578, 482, 1700, 498, 578, 502, 576, 480, 1702, 504, 1678, 478, 600, 480, 1702, 482, 596, 476, 602, 480, 598, 482, 1700, 476, 1708, 480, 1700, 476, 1708, 498, 1684, 480, 1702, 502, 1680, 478, 1704, 482, 596, 480, 606, 470, 598, 480, 598, 476, 602, 476, 1706, 480, 598, 476, 600, 480, 1702, 476, 1708, 480, 598, 560, 518, 554, 524, 548, 530, 482, 1700, 478, 1706, 482, 596, 478, 600, 478, 1704, 480, 1702, 476, 1708, 550}; // COOLIX B21F98 uint64_t data = 0xB21F98;
Timestamp : 000048.482 Library : v2.8.5
Protocol : COOLIX Code : 0xB21F88 (24 Bits) Mesg Desc.: Power: On, Mode: 2 (Auto), Fan: 0 (Auto0), Temp: 28C, Zone Follow: Off, Sensor Temp: Off uint16_t rawData[199] = {4398, 4440, 476, 1708, 480, 598, 474, 1708, 480, 1702, 480, 598, 480, 598, 478, 1704, 476, 602, 500, 576, 478, 1704, 504, 574, 480, 596, 476, 1706, 478, 1704, 478, 600, 504, 1678, 490, 588, 482, 596, 482, 596, 478, 1704, 476, 1706, 478, 1704, 476, 1706, 482, 1700, 474, 1708, 482, 1702, 502, 1680, 480, 598, 476, 600, 482, 596, 474, 604, 478, 600, 478, 1704, 478, 600, 480, 598, 480, 598, 500, 1682, 476, 600, 478, 600, 480, 598, 478, 600, 474, 1708, 474, 1708, 478, 1704, 478, 600, 478, 1704, 482, 1700, 476, 1708, 478, 5280, 4394, 4442, 506, 1678, 476, 602, 480, 1702, 480, 1702, 478, 600, 480, 596, 476, 1706, 478, 600, 500, 578, 478, 1704, 480, 598, 478, 600, 502, 1682, 500, 1682, 502, 576, 504, 1678, 482, 596, 504, 572, 476, 600, 480, 1702, 480, 1702, 480, 1702, 480, 1704, 474, 1708, 480, 1702, 478, 1704, 480, 1702, 476, 602, 474, 604, 476, 600, 478, 600, 476, 600, 498, 1684, 500, 576, 504, 574, 478, 598, 480, 1702, 474, 602, 476, 602, 500, 576, 478, 600, 484, 1698, 476, 1704, 480, 1702, 478, 600, 478, 1702, 478, 1706, 500, 1682, 478}; // COOLIX B21F88 uint64_t data = 0xB21F88;
Timestamp : 000075.045 Library : v2.8.5
Protocol : COOLIX Code : 0xB27BE0 (24 Bits) Mesg Desc.: Power: Off uint16_t rawData[199] = {4396, 4444, 482, 1702, 476, 602, 502, 1680, 478, 1704, 502, 576, 502, 576, 476, 1706, 480, 598, 500, 578, 480, 1704, 502, 576, 476, 602, 482, 1700, 480, 1702, 506, 574, 476, 1704, 504, 574, 500, 1682, 478, 1704, 474, 1708, 478, 1704, 480, 598, 498, 1684, 476, 1706, 476, 1708, 504, 574, 504, 574, 476, 602, 478, 598, 476, 1706, 476, 602, 504, 574, 478, 1704, 476, 1706, 498, 1684, 478, 600, 482, 596, 486, 592, 474, 604, 492, 584, 482, 596, 480, 598, 478, 598, 474, 1708, 480, 1702, 482, 1700, 478, 1704, 476, 1708, 504, 5254, 4398, 4440, 480, 1704, 478, 600, 478, 1704, 476, 1706, 490, 588, 474, 602, 476, 1706, 500, 578, 500, 576, 480, 1704, 476, 602, 502, 576, 480, 1702, 478, 1704, 494, 584, 500, 1682, 476, 602, 478, 1704, 478, 1704, 474, 1708, 498, 1684, 480, 598, 478, 1704, 474, 1708, 480, 1702, 476, 602, 478, 600, 500, 578, 482, 596, 498, 1684, 480, 598, 478, 600, 480, 1702, 480, 1702, 478, 1706, 478, 598, 480, 598, 482, 596, 476, 602, 480, 598, 478, 598, 476, 600, 482, 596, 480, 1702, 476, 1706, 474, 1708, 480, 1702, 480, 1702, 476}; // COOLIX B27BE0 uint64_t data = 0xB27BE0;
After receiving the infrared code, Coolix will reset the sensorTemperature to 0.00, which will become uncontrollable
Interesting, because my testing it seems to report the sensorTemperature as 31.
Regardless, I think the problem is it's reporting a sensor temp in the .toCommon()
method when it shouldn't be.
@hassbian-ABC Can you please download and test PR #2015 / branch Issue2012 and confirm if that fixes your problem.
Thanks in advance.
@NiKiZe The continuous build is failing due to what seems to be an update in the Blynk library behaviour. The failing test should be fixed by https://github.com/crankyoldgit/IRremoteESP8266/pull/2016. When approved & merged, I'll rebase and merge etc.
Okay, I'll test it later @crankyoldgit
Everything has changed very well @crankyoldgit
Thank you @crankyoldgit
When coolix receives the infrared code from the remote control, it becomes uncontrollable