Closed rcottingham closed 1 year ago
Unable to validate the tests in the following group:
cfhd_15_30_60-local/ sequential-track-playback__t21.html sequential-track-playback__t22.html sequential-track-playback__t24.html sequential-track-playback__t26.html sequential-track-playback__t27.html sequential-track-playback__t28.html sequential-track-playback__t29.html sequential-track-playback__t30.html sequential-track-playback__t31.html sequential-track-playback__t32.html sequential-track-playback__t33.html
This is due to the QR code content showing “60 seconds” instead of “1 minute”
The latest mezzanine release (v3) has been checked (by Nicholas Frame) and the mezzanine content has the correct QR codes, indicating the wrong mezzanine has been used.
For further details on the issue please see: Eurofins CTA WAVE Test Suite validation of the Observation Framework results including analysis 31 Jan 2023.xls
Content updated.
This was fixed per Romain. Close.
Unable to validate the tests in the following group:
This is due to the QR code content showing “60 seconds” instead of “1 minute”
The latest mezzanine release (v3) has been checked (by Nicholas Frame) and the mezzanine content has the correct QR codes, indicating the wrong mezzanine has been used.
For further details on the issue please see: Eurofins CTA WAVE Test Suite validation of the Observation Framework results including analysis 31 Jan 2023.xls