For some reason after working without problems on GCP, our sidecar instance now fails with the following error:
> mongo-k8s-sidecar@0.1.0 start /opt/cvallance/mongo-k8s-sidecar
> forever src/index.js
warn: --minUptime not set. Defaulting to: 1000ms
warn: --spinSleepTime not set. Your script will exit if it does not stay up for at least 1000ms
Using mongo port: 27017
Starting up mongo-k8s-sidecar
The cluster domain 'cluster.local' was successfully verified.
Error in workloop { MongoError: connection 0 to 127.0.0.1:27017 timed out
at Function.MongoError.create (/opt/cvallance/mongo-k8s-sidecar/node_modules/mongodb-core/lib/error.js:29:11)
at Socket.<anonymous> (/opt/cvallance/mongo-k8s-sidecar/node_modules/mongodb-core/lib/connection/connection.js:200:20)
at Object.onceWrapper (events.js:273:13)
at Socket.emit (events.js:182:13)
at Socket._onTimeout (net.js:452:8)
at listOnTimeout (timers.js:324:15)
at processTimers (timers.js:268:5)
name: 'MongoError',
message: 'connection 0 to 127.0.0.1:27017 timed out' }
For some reason after working without problems on GCP, our sidecar instance now fails with the following error:
Complete log is here: sidecar.txt
Our statefulset.yml is the following: