cyr-ius / hass-cozytouch

Cozytouch support for Home Assistant
GNU General Public License v2.0
23 stars 14 forks source link

no climate. #11

Open jybi89 opened 4 years ago

jybi89 commented 4 years ago

Hi ! I need help to integrate cozytouch via HACS Could help me please ? I integrated cozytouch with hacs I have only entities sensor température and energy, BUT no climat and no water.

I have to command a central pump heater and water heater, This : https://www.mychauffage.com/produit/pompes-a-chaleur-alfea-extensa-duo-atlantic?gclid=Cj0KCQjw1Iv0BRDaARIsAGTWD1syAWmJwI7bnWnDuk1ORXZ3jk2T8Fi3yrBUEjauqbYfvqYaL_UOdqsaApeiEALw_wcB

thanks for your answer ! jybi89

cyr-ius commented 4 years ago

please test version 1.4.5 (with HACS , enable Beta Version on my component)

jybi89 commented 4 years ago

Thank you for your reply, I replaced the contents of the Custom custom_components \ cozytouch \ * directory and restart HA

image

I still have not climate and water.

I am French, sorry for my English ^^

davoloko commented 4 years ago

Hi @Cyr-ius, thanks for this work!! I have the same issue, when add integration I can see 2 devices Captura de pantalla 2020-05-27 a las 16 22 27 But when select the device only shows this entity: Captura de pantalla 2020-05-27 a las 16 23 04 Captura de pantalla 2020-05-27 a las 16 23 13

I'm using 1.4.5 version.

I have Alfea Extensa AI (this model support heating and cooling). I control the heater with navilink a59 and have the Cozytouch bridge to connect Cozytouch app

Thanks in advance!!

cyr-ius commented 4 years ago

Please enable debug , view issue #8 and post Je suis français donc si c'est plus facile pour toi. Écrit en français. Je pense que tu as un équipement assez similaire a @Palm17 , qui a ouvert l issue 8

davoloko commented 4 years ago

Thanks @Cyr-ius! attach the homeassistant log. I deleted some fields for privacy. If you need any of them I can send them to you privately. Thank you! home-assistant.log

palm17 commented 4 years ago

I have a boiler Naema heater boiler only - the domestic hot water is produce with a separate tank and the heater. I have an A59 too. It is not the same equipment, but the protocol of communication is the same.

cyr-ius commented 4 years ago

OK , please test version 1.4.8 (beta) Add Heater from Heating Zone Add DHW from APC Water Heater I've add a service to select mode for a boiler. (Please look service in HA)

Thanks @Cyr-ius! attach the homeassistant log. I deleted some fields for privacy. If you need any of them I can send them to you privately. Thank you! home-assistant.log

OK , please test version 1.4.8 (beta) Add Heater from Heating Zone Add DHW from APC Water Heater I've add a service to select mode for a boiler. (Please look service in HA)

Future : add heat pump

davoloko commented 4 years ago

Thanks a lot!! Now I can see climate and other sensor but I can't modify the climate values. when I try to change the off (default) mode to another, e.g. hot/cold (or any other), it goes back to off and does not hold. It also does not show an error. With the default settings, an error does appear (image attached) I also attach the error logs

Captura de pantalla 2020-05-30 a las 16 12 12 Captura de pantalla 2020-05-30 a las 16 12 37 Captura de pantalla 2020-05-30 a las 16 14 02 Captura de pantalla 2020-05-30 a las 16 14 29 log.txt

Thanks again for your amazing work!

cyr-ius commented 4 years ago

Thanks a lot!! Now I can see climate and other sensor but I can't modify the climate values. when I try to change the off (default) mode to another, e.g. hot/cold (or any other), it goes back to off and does not hold. It also does not show an error. With the default settings, an error does appear (image attached) I also attach the error logs

Captura de pantalla 2020-05-30 a las 16 12 12 Captura de pantalla 2020-05-30 a las 16 12 37 Captura de pantalla 2020-05-30 a las 16 14 02 Captura de pantalla 2020-05-30 a las 16 14 29 log.txt

Thanks again for your amazing work!

I separated the heating from the air conditioning now you have two devices Heating Zona 1 for two temperature ECO/COMFORT Cooling Zona 1 for two temperature ECO/COMFORT Operation Mode is the same on both Preset Mode are specific for a device Please up to 1.4.9

cyr-ius commented 4 years ago

Please check new version 1.5.3