Open Cabooman opened 9 months ago
I have a similar wish regarding the temperature rating or reduced power related to temperatures below 20 degC. Using Goodwe 30 kW inverter with simulated 2*BYD HVM batteries. Ideal would be if the temperature could be "translated" to 21 degC when in the range of -10 to 19,9 degC ? This would allow us to run full power when needed. Without having to heat the batteries at all times.
How do you use batteries? Battery management I3 continuously regulates the recommended charge and discharge value. Keep in mind that at -10 celsius you cannot fully power charging, the battery will be destroyed. As for regulation according to temperature - this is determined by battery management. So your request is duplicated and actually unnecessary. Only the battery management inside the battery has the correct values for setting the limit.
It would be nice to limit charge/discharge power based on the battery temperature, e.g. ramping the power from the stated BMS power capacity at 40 degrees C to 0 W at 50 degrees C. Similarly at low temperature, ramp from BMS max power at -10 and 0 W at -20