Open Ricks88 opened 1 year ago
Here is an example URL, which is JSON (so not either XML or HTML): https://www.metservice.com/publicData/webdata/warnings-service/urban/auckland
This error originated from a custom integration.
Logger: py.warnings
Source: custom_components/multiscrape/scraper.py:59
Integration: Multiscrape scraping component (documentation, issues)
First occurred: 09:30:42 (3 occurrences)
Last logged: 09:57:32
/usr/local/lib/python3.11/site-packages/bs4/builder/__init__.py:545: XMLParsedAsHTMLWarning: It looks like you're parsing an XML document using an HTML parser. If this really is an HTML document (maybe it's XHTML?), you can ignore or filter this warning. If it's XML, you should know that using an XML parser will be more reliable. To parse this document as XML, make sure you have the lxml package installed, and pass the keyword argument `features="xml"` into the BeautifulSoup constructor. warnings.warn(
Same here, and same issues as https://github.com/danieldotnl/ha-multiscrape/issues/220 The suggested solution didn't solve it. Currently is flooding the HA logs for every time it runs, even after setting parser: 'lxml'.
There should be a way to filter out this specific warning. Or maybe reduce the criticality to WARN or INFO so that it can be filtered by native log support? https://community.home-assistant.io/t/how-to-exclude-a-specific-warning-from-log/38761/13?u=diamant-x
Thanks.
Is there any solution for this?
Is there any solution for this?
@diamant-x @stephan1827
I just use this in the logger:
logger: default: warning
filters: homeassistant:
"Error doing job: Task exception was never retrieved"
homeassistant.loader:
"It looks like you're parsing an XML document using an HTML parser"
pychromecast.socket_client:
homeassistant.loader:
Wonderful, will try, thanks! PD: How did you identified this was the filter component to use?
Nice workaround! It would help me a lot if someone can provide me a configuration to reproduce this. https://hp-officejet.local doesn't work for me :)
homeassistant.loader:
Wonderful, will try, thanks! PD: How did you identified this was the filter component to use?
I did not, i just looked at the logs and copy the first words of the notification i do not want to see anymore. Maybe just only
Nice workaround! It would help me a lot if someone can provide me a configuration to reproduce this. https://hp-officejet.local doesn't work for me :)
Use the IP of your own printer..
OR
Just start using my instant_ink_print_plan yaml
https://github.com/Ricks88/HASS_HPInstantInk/tree/main
No more need of ping sensor and multiscrape or any XML errors.
@Ricks88 I tried the log filter but I still get the log entries. My entry looks like this.
logger:
default: warning
filters:
homeassistant:
- "Error doing job: Task exception was never retrieved"
homeassistant.loader:
- "We found a custom integration"
- "XMLParsedAsHTMLWarning"
- "It looks like you're parsing an XML document using an HTML parser"
Is there something wrong in the formating?
@Ricks88 I tried the log filter but I still get the log entries. My entry looks like this.
Is there something wrong in the formating?
@stephan1827 @danieldotnl
Yes, sorry!
Correct config:
logger:
default: warning
filters:
homeassistant:
- "Error doing job: Task exception was never retrieved"
homeassistant.loader:
- "We found a custom integration"
pychromecast.socket_client:
- "Failed to connect to service ServiceInfo"
- "Error communicating with socket, resetting connection"
py.warnings:
# Ignore the BeautifulSoup XML parser error with Multiscrape and HP Printer XML file.
- "XMLParsedAsHTMLWarning"
@Ricks88 Thx that worked
I reproduced this issue and setting the parser to xml
seems to solve it for me. Could you give it a try and confirm?
Just tried it and the error is still there. Do I have to change the parser option, too. Mine is set to lxml.
Try setting it to 'xml' and let me know pls
When I do that I get
Consider using debug logging and log_response for further investigation. 2024-04-03 10:04:25.425 ERROR (MainThread) [custom_components.multiscrape.sensor] Scraper_noname_0 # Piko yield total (Wh) # Unable to scrape data: Could not find a tag for given selector
This is my configuration
# -------------------------------------------------------
# PIKO inverter
multiscrape:
- resource: http://192.168.30.82/all.xml
scan_interval: 15 # Kann auch grobmaschiger abgefragt werden z.B. 60s
parser: xml
sensor:
- unique_id: kostal_piko_ac_power
name: "Piko AC Power"
select: "measurement[type='AC_Power']"
attribute: "value"
unit_of_measurement: "W"
on_error:
log: 'info'
value: "default"
default: 0.0
- unique_id: kostal_piko_yield_total_Wh
name: "Piko yield total (Wh)"
select: "yieldvalue"
attribute: "value"
unit_of_measurement: "Wh"
state_class: total_increasing
device_class: energy
and here is the xml data from the inverter
This XML file does not appear to have any style information associated with it. The document tree is shown below.
<root>
<Device Name="PIKO 2.5-1 MP plus" Type="Inverter" Platform="Net16" HmiPlatform="HMI17" NominalPower="2500" UserPowerLimit="nan" CountryPowerLimit="nan" Serial="763166EG006884130005" OEMSerial="10351313" BusAddress="1" NetBiosName="INV006884130005" WebPortal="PIKO Solar Portal" ManufacturerURL="kostal-solar-electric.com" IpAddress="192.168.30.82" DateTime="2024-04-03T09:04:21" MilliSeconds="207">
<Siblings/>
<CanOpen Status="not started"/>
<Measurements>
<Measurement Value="223.8" Unit="V" Type="AC_Voltage"/>
<Measurement Value="1.213" Unit="A" Type="AC_Current"/>
<Measurement Value="271.8" Unit="W" Type="AC_Power"/>
<Measurement Value="273.6" Unit="W" Type="AC_Power_fast"/>
<Measurement Value="49.991" Unit="Hz" Type="AC_Frequency"/>
<Measurement Value="269.0" Unit="V" Type="DC_Voltage"/>
<Measurement Value="1.114" Unit="A" Type="DC_Current"/>
<Measurement Value="330.0" Unit="V" Type="LINK_Voltage"/>
<Measurement Unit="W" Type="GridPower"/>
<Measurement Unit="W" Type="GridConsumedPower"/>
<Measurement Unit="W" Type="GridInjectedPower"/>
<Measurement Unit="W" Type="OwnConsumedPower"/>
<Measurement Value="100.0" Unit="%" Type="Derating"/>
</Measurements>
<Events>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2024-04-02T10:41:52" End="2024-04-02T10:44:07"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2024-04-02T10:41:52" End="2024-04-02T10:44:07"/>
<Event Id="1" Message="ENS Grid Frequency too low" Severity="Error" Type="User" Start="2023-12-21T10:28:54" End="2023-12-21T10:28:55"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2023-12-21T10:28:54" End="2023-12-21T10:31:25"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2023-10-24T13:22:44" End="2023-10-24T13:22:45"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2023-10-24T13:22:44" End="2023-10-24T13:22:48"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2023-08-16T11:25:23" End="2023-08-16T11:25:24"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2023-08-16T11:25:23" End="2023-08-16T11:27:38"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2023-08-16T11:14:41" End="2023-08-16T11:14:41"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2023-08-16T11:14:41" End="2023-08-16T11:22:47"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2023-07-30T10:15:00" End="2023-07-30T10:15:11"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2023-07-30T10:15:00" End="2023-07-30T10:15:11"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2023-04-28T14:06:01" End="2023-04-28T14:06:34"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2023-04-28T14:06:01" End="2023-04-28T14:06:34"/>
<Event Id="33" Message="PU SW version incompatible" Severity="Info" Type="User" Start="2023-02-25T08:50:39" End="2023-02-25T09:21:43"/>
<Event Id="85" Message="PU OEM variant mismatch" Severity="Error" Type="User" Start="2023-02-25T08:50:19" End="2023-02-25T09:23:23"/>
<Event Id="38" Message="ENS Reading countrycode failed" Severity="Error" Type="User" Start="2023-02-25T08:50:18" End="2023-02-25T09:23:23"/>
<Event Id="85" Message="PU OEM variant mismatch" Severity="Error" Type="User" Start="2023-02-25T08:45:14" End="2023-02-25T08:50:10"/>
<Event Id="33" Message="PU SW version incompatible" Severity="Info" Type="User" Start="2023-02-25T08:45:32" End="2023-02-25T08:48:28"/>
<Event Id="38" Message="ENS Reading countrycode failed" Severity="Error" Type="User" Start="2023-02-25T08:45:13" End="2023-02-25T08:50:10"/>
<Event Id="33" Message="PU SW version incompatible" Severity="Info" Type="User" Start="2023-02-25T08:07:52" End="2023-02-25T08:45:03"/>
<Event Id="85" Message="PU OEM variant mismatch" Severity="Error" Type="User" Start="2023-02-25T08:07:33" End="2023-02-25T08:45:03"/>
<Event Id="38" Message="ENS Reading countrycode failed" Severity="Error" Type="User" Start="2023-02-25T08:07:32" End="2023-02-25T08:45:03"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2022-11-27T11:44:56" End="2022-11-27T11:44:56"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2022-11-27T11:44:56" End="2022-11-27T11:45:13"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2022-11-19T09:55:22" End="2022-11-19T09:55:23"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2022-11-19T09:55:22" End="2022-11-19T09:55:36"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2022-10-23T09:05:39" End="2022-10-23T09:05:55"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2022-10-23T09:05:39" End="2022-10-23T09:05:55"/>
<Event Id="11" Message="ENS DC Offset too high" Severity="Error" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="12" Message="ENS residual current too high" Severity="Error" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="122" Message="PU Battery manager values missing" Severity="Warning" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="34" Message="ENS Remote Tripping" Severity="Warning" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="82" Message="DRM0 opencircuit" Severity="Error" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="121" Message="Check grid support config" Severity="Error" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="43" Message="ENS Grid Voltage too high L1" Severity="Error" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="5" Message="ENS Grid Voltage too low for reconnect" Severity="Error" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="6" Message="ENS Grid Voltage too high for reconnect" Severity="Error" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="7" Message="ENS Grid AVG Voltage too low" Severity="Error" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="1" Message="ENS Grid Frequency too low" Severity="Error" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="2" Message="ENS Grid Frequency too high" Severity="Error" Type="User" Start="2022-10-22T11:08:59" End="2022-10-22T11:32:20"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2022-08-03T04:31:25" End="2022-08-03T04:31:52"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2022-08-03T04:31:25" End="2022-08-03T04:31:52"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2022-06-10T09:49:07" End="2022-06-10T09:49:07"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2022-06-10T09:49:07" End="2022-06-10T09:54:30"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2022-05-28T08:09:48" End="2022-05-28T08:22:23"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2022-05-28T08:09:48" End="2022-05-28T08:22:23"/>
<Event Id="5" Message="ENS Grid Voltage too low for reconnect" Severity="Error" Type="User" Start="2022-03-05T08:02:47" End="2022-03-05T08:02:47"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2022-03-05T08:02:47" End="2022-03-05T08:02:47"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2022-03-05T08:02:47" End="2022-03-05T09:03:31"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2022-03-05T08:00:44" End="2022-03-05T08:02:41"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2022-03-05T08:00:44" End="2022-03-05T08:02:41"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2022-03-02T17:03:54" End="2022-03-02T17:04:24"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2022-03-02T17:03:54" End="2022-03-02T17:04:24"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2021-08-13T08:59:56" End="2021-08-13T09:00:46"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2021-08-13T08:59:56" End="2021-08-13T09:00:46"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2021-08-12T07:53:20" End="2021-08-12T07:54:59"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2021-08-12T07:53:20" End="2021-08-12T07:54:59"/>
<Event Id="37" Message="ENS Line connection wrong" Severity="Error" Type="User" Start="2021-06-16T07:10:19" End="2021-06-16T07:10:36"/>
<Event Id="40" Message="ENS Grid Voltage too low L1" Severity="Error" Type="User" Start="2021-06-16T07:10:19" End="2021-06-16T07:10:36"/>
</Events>
<Yields>
<Yield Type="Produced" Slot="Total" Unit="Wh">
<YieldValue Value="8946845" TimeStamp="2020-09-25T13:20:00"/>
</Yield>
</Yields>
<Versions>
<Software Device="HMI" Name="BFAPI STM32F4" Version="2.8.0"/>
<Software Device="HMI" Name="FBL" Version="1.4.0"/>
<Software Device="HMI" Name="APP" Version="3.18.0"/>
<Software Device="HMI" Name="OEM PIKO 2.5-1 MP p" Version="1.0.1"/>
<Software Device="PU" Name="BFAPI SAFE STM32F4" Version="2.8.0"/>
<Software Device="PU" Name="FBL" Version="2.0.3"/>
<Software Device="PU" Name="APP" Version="4.7.0"/>
<Software Device="PU" Name="PAR default" Version="24.0.24"/>
<Software Device="PU" Name="OEM VAR_7_Kostal" Version="1.0.7"/>
<Software Device="ENS1" Name="APP" Version="1.35.0"/>
<Hardware Device="HMI" Version="1"/>
<Hardware Device="PU" Version="5"/>
</Versions>
<State Value="Standby"/>
<Tasks/>
<Statistics>
<Statistic Name="Common">
<Value Label="Connected%20To%20Grid">71832415</Value>
<Value Label="Active">34706282</Value>
</Statistic>
<Statistic Name="Power">
<Value Label="0-50W">5212456</Value>
<Value Label="50-100W">3660647</Value>
<Value Label="100-200W">4569596</Value>
<Value Label="200-500W">6926171</Value>
<Value Label="500-1000W">5500647</Value>
<Value Label="1000-2000W">5873724</Value>
<Value Label="2000-5000W">2963041</Value>
<Value Label="5000-10000W">0</Value>
</Statistic>
<Statistic Name="AC%20Voltage%201">
<Value Label="%3C200V">5002</Value>
<Value Label="200-210V">5</Value>
<Value Label="210-220V">4458</Value>
<Value Label="220-230V">60011127</Value>
<Value Label="230-240V">11806666</Value>
<Value Label="240-250V">618</Value>
<Value Label="250-255V">0</Value>
<Value Label="255-260V">0</Value>
<Value Label="260-265V">0</Value>
<Value Label="%3E265V">0</Value>
</Statistic>
<Statistic Name="PV%20Voltage%201">
<Value Label="%3C100V">0</Value>
<Value Label="100-200V">0</Value>
<Value Label="200-300V">0</Value>
<Value Label="300-400V">0</Value>
<Value Label="400-500V">0</Value>
<Value Label="500-600V">0</Value>
<Value Label="600-700V">0</Value>
<Value Label="700-800V">0</Value>
<Value Label="800-850V">0</Value>
<Value Label="850-900V">0</Value>
<Value Label="900-950V">0</Value>
<Value Label="950-1000V">0</Value>
<Value Label="%3E1000V">0</Value>
</Statistic>
<Statistic Name="Derating">
<Value Label="Temperature">0</Value>
<Value Label="External">50</Value>
<Value Label="P(f)">751</Value>
<Value Label="Startup">4318</Value>
<Value Label="UserLimit">0</Value>
<Value Label="Hardware%20Limit">0</Value>
<Value Label="Frequency%20TooHigh">0</Value>
</Statistic>
<Statistic Name="Temp%20Ambient">
<Value Label="%3C-20%C2%B0C">0</Value>
<Value Label="-20-0%C2%B0C">0</Value>
<Value Label="0-20%C2%B0C">9671993</Value>
<Value Label="20-40%C2%B0C">57466469</Value>
<Value Label="40-60%C2%B0C">4046873</Value>
<Value Label="60-80%C2%B0C">18449</Value>
<Value Label="80-100%C2%B0C">220</Value>
<Value Label="%3E100%C2%B0C">628411</Value>
</Statistic>
<Statistic Name="Temp%20T1">
<Value Label="%3C-20%C2%B0C">0</Value>
<Value Label="-20-0%C2%B0C">0</Value>
<Value Label="0-20%C2%B0C">13897338</Value>
<Value Label="20-40%C2%B0C">44713372</Value>
<Value Label="40-60%C2%B0C">13217167</Value>
<Value Label="60-80%C2%B0C">0</Value>
<Value Label="80-100%C2%B0C">0</Value>
<Value Label="%3E100%C2%B0C">0</Value>
</Statistic>
<Statistic Name="Temp%20T2">
<Value Label="%3C-20%C2%B0C">0</Value>
<Value Label="-20-0%C2%B0C">0</Value>
<Value Label="0-20%C2%B0C">13897338</Value>
<Value Label="20-40%C2%B0C">44713372</Value>
<Value Label="40-60%C2%B0C">13217167</Value>
<Value Label="60-80%C2%B0C">0</Value>
<Value Label="80-100%C2%B0C">0</Value>
<Value Label="%3E100%C2%B0C">0</Value>
</Statistic>
<Statistic Name="Temp%20T3">
<Value Label="%3C-20%C2%B0C">0</Value>
<Value Label="-20-0%C2%B0C">0</Value>
<Value Label="0-20%C2%B0C">13897338</Value>
<Value Label="20-40%C2%B0C">44713372</Value>
<Value Label="40-60%C2%B0C">13217167</Value>
<Value Label="60-80%C2%B0C">0</Value>
<Value Label="80-100%C2%B0C">0</Value>
<Value Label="%3E100%C2%B0C">0</Value>
</Statistic>
<Statistic Name="Temp%20T4">
<Value Label="%3C-20%C2%B0C">0</Value>
<Value Label="-20-0%C2%B0C">0</Value>
<Value Label="0-20%C2%B0C">13897338</Value>
<Value Label="20-40%C2%B0C">44713372</Value>
<Value Label="40-60%C2%B0C">13217167</Value>
<Value Label="60-80%C2%B0C">0</Value>
<Value Label="80-100%C2%B0C">0</Value>
<Value Label="%3E100%C2%B0C">0</Value>
</Statistic>
<Statistic Name="PU%20Tmax">
<Value Label="%3C-20%C2%B0C">0</Value>
<Value Label="-20-0%C2%B0C">0</Value>
<Value Label="0-20%C2%B0C">13897465</Value>
<Value Label="20-40%C2%B0C">38573348</Value>
<Value Label="40-60%C2%B0C">17063338</Value>
<Value Label="60-80%C2%B0C">2293726</Value>
<Value Label="80-100%C2%B0C">0</Value>
<Value Label="%3E100%C2%B0C">0</Value>
</Statistic>
</Statistics>
<Settings>
<PowerLimit Value="2500" Valid="false"/>
<DateTimeFormat Date="dd.mm.yyyy" Time="24h"/>
</Settings>
<ReactivePower>
<Curve Type="cosPhi = 1" XUnit="‰" YUnit="">
<Point X="0" Y="1000"/>
<Point X="1000" Y="1000"/>
</Curve>
<Parameters>
<Parameter Name="PowerFactor" Value="0.0" Unit="%"/>
<Parameter Name="Q fix" Value="0.0" Unit="var"/>
<Parameter Name="φ PLockIn" Value="10.0" Unit="%"/>
<Parameter Name="φ PLockOut" Value="10.0" Unit="%"/>
<Parameter Name="Q dynamik" Value="3.3" Unit="s"/>
</Parameters>
</ReactivePower>
<GridParameters CountryCode="4901" CountryName="D AR4105:2019">
<GridParameter ID="24" SortID="20" Name="t Reconnect" Value="60.00" Min="0.00" Max="1200.00" Unit="s" Var="true" Default="60.00"/>
<GridParameter ID="92" SortID="22" Name="t Startup" Value="60.00" Min="0.00" Max="1200.00" Unit="s" Var="true" Default="60.00"/>
<GridParameter ID="25" SortID="30" Name="Recon Grad" Value="10.00" Min="6.00" Max="3000.00" Unit="%" Var="true" Default="10.00"/>
<GridParameter ID="83" SortID="31" Name="StartupGrad" Value="100.00" Min="0.00" Max="3000.00" Unit="%" Var="true" Default="100.00"/>
<GridParameter ID="93" SortID="32" Name="Extern Grad" Value="39.40" Min="0.00" Max="30000.00" Unit="%" Var="true" Default="39.40"/>
<GridParameter ID="0" SortID="90" Name="U n" Value="230.00" Min="100.00" Max="240.00" Unit="V" Var="true" Default="230.00"/>
<GridParameter ID="10" SortID="100" Name="U > recon" Value="110.00" Min="100.00" Max="135.00" Unit="%" Var="true" Default="110.00"/>
<GridParameter ID="49" SortID="130" Name="U >>" Value="125.00" Min="100.00" Max="135.00" Unit="%" Var="true" Default="125.00"/>
<GridParameter ID="50" SortID="140" Name="t(U >>)" Value="0.20" Min="0.00" Max="180.00" Unit="s" Var="true" Default="0.20"/>
<GridParameter ID="9" SortID="150" Name="U < recon" Value="85.00" Min="5.00" Max="100.00" Unit="%" Var="true" Default="85.00"/>
<GridParameter ID="1" SortID="160" Name="U <" Value="80.00" Min="5.00" Max="100.00" Unit="%" Var="true" Default="80.00"/>
<GridParameter ID="2" SortID="170" Name="t(U <)" Value="3.00" Min="0.00" Max="180.00" Unit="s" Var="true" Default="3.00"/>
<GridParameter ID="51" SortID="180" Name="U <<" Value="45.00" Min="5.00" Max="100.00" Unit="%" Var="true" Default="45.00"/>
<GridParameter ID="52" SortID="190" Name="t(U <<)" Value="0.40" Min="0.00" Max="180.00" Unit="s" Var="true" Default="0.40"/>
<GridParameter ID="7" SortID="220" Name="U >" Value="110.00" Min="110.00" Max="115.00" Unit="%" Var="true" Default="110.00"/>
<GridParameter ID="8" SortID="230" Name="t(U >)" Value="600.00" Min="1.00" Max="603.00" Unit="s" Var="true" Default="600.00"/>
<GridParameter ID="84" SortID="270" Name="U HVRT" Value="115.00" Min="100.00" Max="135.00" Unit="%" Var="true" Default="115.00"/>
<GridParameter ID="85" SortID="275" Name="U LVRT" Value="80.00" Min="5.00" Max="100.00" Unit="%" Var="true" Default="80.00"/>
<GridParameter ID="11" SortID="320" Name="f n" Value="50.00" Min="50.00" Max="60.00" Unit="Hz" Var="false" Default="50.00"/>
<GridParameter ID="22" SortID="410" Name="f > recon" Value="50.10" Min="47.50" Max="51.50" Unit="Hz" Var="true" Default="50.10"/>
<GridParameter ID="14" SortID="420" Name="f >" Value="51.50" Min="50.00" Max="55.00" Unit="Hz" Var="true" Default="51.50"/>
<GridParameter ID="15" SortID="430" Name="t(f >)" Value="0.20" Min="0.05" Max="100.00" Unit="s" Var="true" Default="0.20"/>
<GridParameter ID="21" SortID="480" Name="f < recon" Value="47.50" Min="47.50" Max="51.50" Unit="Hz" Var="true" Default="47.50"/>
<GridParameter ID="12" SortID="490" Name="f <" Value="47.50" Min="45.00" Max="50.00" Unit="Hz" Var="true" Default="47.50"/>
<GridParameter ID="13" SortID="500" Name="t(f <)" Value="0.20" Min="0.05" Max="100.00" Unit="s" Var="true" Default="0.20"/>
<GridParameter ID="33" SortID="550" Name="I DCRelInom" Value="0.50" Min="0.10" Max="10.00" Unit="%" Var="true" Default="0.50"/>
<GridParameter ID="35" SortID="570" Name="t(IDC rel)" Value="5.00" Min="0.02" Max="5.00" Unit="s" Var="true" Default="5.00"/>
<GridParameter ID="26" SortID="600" Name="P(f)+ Grad" Value="40.00" Min="10.00" Max="1000.00" Unit="%/Hz" Var="true" Default="40.00"/>
<GridParameter ID="20" SortID="610" Name="P(f)+ Start" Value="50.20" Min="50.20" Max="50.50" Unit="Hz" Var="true" Default="50.20"/>
<GridParameter ID="62" SortID="630" Name="P(f)+ Exit" Value="50.20" Min="50.00" Max="50.20" Unit="Hz" Var="true" Default="50.20"/>
<GridParameter ID="74" SortID="650" Name="P(f) ExGrad" Value="10.00" Min="0.00" Max="100.00" Unit="%" Var="true" Default="10.00"/>
<GridParameter ID="86" SortID="660" Name="P(f)- Grad" Value="40.00" Min="16.60" Max="100.00" Unit="%/Hz" Var="true" Default="40.00"/>
<GridParameter ID="73" SortID="670" Name="P(f)- Exit" Value="49.80" Min="49.80" Max="50.00" Unit="Hz" Var="true" Default="49.80"/>
<GridParameter ID="70" SortID="680" Name="P(f)- Start" Value="49.80" Min="46.00" Max="50.00" Unit="Hz" Var="true" Default="49.80"/>
<GridParameter ID="65" SortID="800" Name="P(U) Modus" Value="0.00" Min="0.00" Max="2.00" Unit="" Var="true" Default="0.00"/>
<GridParameter ID="66" SortID="810" Name="P(U)+ Entry" Value="110.00" Min="0.00" Max="250.00" Unit="%" Var="true" Default="110.00"/>
<GridParameter ID="67" SortID="820" Name="P(U)+ End" Value="112.00" Min="0.00" Max="250.00" Unit="%" Var="true" Default="112.00"/>
<GridParameter ID="76" SortID="850" Name="P(U) dyn" Value="5.00" Min="0.00" Max="120.00" Unit="s" Var="true" Default="5.00"/>
<GridParameter ID="45" SortID="930" Name="φ PLockIn" Value="10.00" Min="0.00" Max="100.00" Unit="%" Var="true" Default="10.00"/>
<GridParameter ID="46" SortID="940" Name="φ PLockOut" Value="10.00" Min="0.00" Max="100.00" Unit="%" Var="true" Default="10.00"/>
<GridParameter ID="87" SortID="990" Name="φ Limit" Value="0.35" Min="0.14" Max="1.00" Unit="" Var="true" Default="0.35"/>
<GridParameter ID="58" SortID="1000" Name="Q fix" Value="0.00" Min="-1089.00" Max="1089.00" Unit="var" Var="true" Default="0.00"/>
<GridParameter ID="97" SortID="1020" Name="Q PLockIn" Value="0.00" Min="0.00" Max="100.00" Unit="%" Var="true" Default="0.00"/>
<GridParameter ID="98" SortID="1030" Name="Q PLockOut" Value="0.00" Min="0.00" Max="100.00" Unit="%" Var="true" Default="0.00"/>
<GridParameter ID="47" SortID="1040" Name="Q dynamik" Value="3.33" Min="0.00" Max="60.00" Unit="s" Var="true" Default="3.33"/>
<GridParameter ID="38" SortID="1360" Name="R iso Ohm/V" Value="1000.00" Min="0.00" Max="1000.00" Unit="R/V" Var="true" Default="1000.00"/>
<GridParameter ID="48" SortID="1390" Name="RapidShut" Value="1.00" Min="0.00" Max="1.00" Unit="" Var="true" Default="1.00"/>
<GridParameter ID="39" SortID="1420" Name="P UserLimit" Value="2500.00" Min="0.00" Max="2500.00" Unit="W" Var="true" Default="2500.00"/>
<GridParameter ID="82" SortID="1440" Name="PvScanOnOff" Value="1.00" Min="0.00" Max="1.00" Unit="" Var="true" Default="1.00"/>
</GridParameters>
<WebPortals>
<WebPortal Name="PIKO Solar Portal" Protocol="HTTP" URL="www.pikoloop.de" Path="/impsrv" Port="80" Active="true"/>
</WebPortals>
</Device>
</root>
@stephan1827 So I tried to reproduce your scenario. I set up a local web server serving your xml. Then I use your configuration to scrape it. Indeed it doesn't work with parser: xml
, but if change that into lxml
I don't see the warning from BeautifulSoup. Do you still see that?
Yep, its still there
2024-04-07 18:28:31.571 WARNING (SyncWorker_2) [py.warnings] /usr/local/lib/python3.12/concurrent/futures/thread.py:58: XMLParsedAsHTMLWarning: It looks like you're parsing an XML document using an HTML parser. If this really is an HTML document (maybe it's XHTML?), you can ignore or filter this warning. If it's XML, you should know that using an XML parser will be more reliable. To parse this document as XML, make sure you have the lxml package installed, and pass the keyword argument `features="xml"` into the BeautifulSoup constructor.
Hello,
Not sure if this is a Issue/bug, but I am getting this new error: Deze fout is ontstaan door een aangepaste integratie.
Logger: py.warnings Source: custom_components/multiscrape/scraper.py:59 Integration: Multiscrape scraping component (documentation, issues) First occurred: 16:25:02 (2 occurrences) Last logged: 16:26:07
/usr/local/lib/python3.11/site-packages/bs4/builder/init.py:545: XMLParsedAsHTMLWarning: It looks like you're parsing an XML document using an HTML parser. If this really is an HTML document (maybe it's XHTML?), you can ignore or filter this warning. If it's XML, you should know that using an XML parser will be more reliable. To parse this document as XML, make sure you have the lxml package installed, and pass the keyword argument
features="xml"
into the BeautifulSoup constructor. warnings.warn(My code is: `multiscrape:
I only have used BS4 as Package into AppDeamon, I dont understand why it is using BS4 in the multiscrape or how to use XML parser instead.