Closed GoogleCodeExporter closed 8 years ago
The billing tool is working correctly in our tests.
If you collect the data in PRTG from 11/1/2011 to 12/1/2011, this means you
include everything between 11/1/2011 12:00:00 am and 12/1/2011 11:59:59 pm. If
you do the same thing for December like 12/1/2011 12:00:00 am to 1/1/2012
11:59:59 pm you have collected the data for the 1st of December twice.
You might want to try something like this, to get a better overview over your
data:
Open the sensor, you want to get the data from in the PRTG Ajax Web GUI. Go to
the tab "Settings". Set "Sensor Display" > "Primary Channel" to "Traffic Out"(I
suppose, that is the channel you are using for the billing). You won’t lose
any data by switching the default channel.
Now open the tab "Historic Data". You will find a button "Last Month" in the
quick range selection you can use. Set "File Format" to "HTML web page" and the
"Average Interval" to "24 Hours/1 Day". Now click the "Start Button". The
created HTML-File will be directly opened in your web browser.
This way, you can see the traffic for the whole month(the last entry in the
first box on top of the page) and for every single day(the column “Traffic
Out (volume)” in the table below).
If you compare those values to the billing tool, you will see, that they are a
match.(Please notice, that all values are rounded up in the billing tool, so
1.1GB will for example be shown as 2GB)
When you are done with the test, you can change the primary channel in the
settings back to your original value. This setting was only needed, so the
report would show the total for the right channel.
I hope my answer was of any help for you.
Original comment by joherrm...@gmail.com
on 18 Jan 2012 at 11:19
Original comment by gerard.f...@gmail.com
on 24 Apr 2012 at 10:08
Original issue reported on code.google.com by
pydotc...@gmail.com
on 24 Dec 2011 at 10:08