Open fsedarkalex opened 7 months ago
Try in the Modbus :
- name: Total active power
unique_id: total_active_power
device_address: 3
address: 1348
input_type: input
data_type: int16
precision: 0
unit_of_measurement: W
device_class: power
state_class: measurement
scale: 1
scan_interval: 10
- name: L1 active power
unique_id: l1_active_power
device_address: 3
address: 1349
input_type: input
data_type: int16
precision: 0
unit_of_measurement: W
device_class: power
state_class: measurement
scale: 1
scan_interval: 10
- name: L1 Grid Current
unique_id: l1_grid_current
device_address: 3
address: 16434
input_type: input
data_type: int16
precision: 2
unit_of_measurement: A
device_class: Current
state_class: measurement
scale: 0.01
scan_interval: 60
- name: L1 Grid active voltage
unique_id: l1_grid_active_voltage
device_address: 3
address: 16433
input_type: input
data_type: uint16
precision: 1
unit_of_measurement: V
device_class: Voltage
state_class: measurement
scale: 0.1
scan_interval: 60
- name: L1 Grid Freq
unique_id: l1_grid_freq
device_address: 3
address: 16435
input_type: input
data_type: uint16
precision: 2
unit_of_measurement: Hz
device_class: Frequency
state_class: measurement
scale: 0.01
scan_interval: 60
- name: L1 Grid DCI
unique_id: l1_grid_dci
device_address: 3
address: 16434
input_type: input
data_type: int16
precision: 2
unit_of_measurement: A
device_class: Current
state_class: measurement
scale: 1000
scan_interval: 60
- name: L2 active power
unique_id: l2_active_power
device_address: 3
address: 1350
input_type: input
data_type: int16
precision: 0
unit_of_measurement: W
device_class: power
state_class: measurement
scale: 1
scan_interval: 10
- name: L2 Grid Current
unique_id: l2_grid_current
device_address: 3
address: 16441
input_type: input
data_type: int16
precision: 2
unit_of_measurement: A
device_class: Current
state_class: measurement
scale: 0.01
scan_interval: 60
- name: L2 Grid active voltage
unique_id: l2_grid_active_voltage
device_address: 3
address: 16440
input_type: input
data_type: uint16
precision: 1
unit_of_measurement: V
device_class: Voltage
state_class: measurement
scale: 0.1
scan_interval: 60
- name: L2 Grid Freq
unique_id: l2_grid_freq
device_address: 3
address: 16442
input_type: input
data_type: uint16
precision: 2
unit_of_measurement: Hz
device_class: Frequency
state_class: measurement
scale: 0.01
scan_interval: 60
- name: L2 Grid DCI
unique_id: l2_grid_dci
device_address: 3
address: 164443
input_type: input
data_type: int16
precision: 2
unit_of_measurement: A
device_class: Current
state_class: measurement
scale: 1000
scan_interval: 60
- name: L3 active power
unique_id: l3_active_power
device_address: 3
address: 1351
input_type: input
data_type: int16
precision: 0
unit_of_measurement: W
device_class: power
state_class: measurement
scale: 1
scan_interval: 10
- name: L3 Grid Current
unique_id: l3_grid_current
device_address: 3
address: 16448
input_type: input
data_type: int16
precision: 2
unit_of_measurement: A
device_class: Current
state_class: measurement
scale: 0.01
scan_interval: 60
- name: L3 Grid active voltage
unique_id: l3_grid_active_voltage
device_address: 3
address: 16447
input_type: input
data_type: uint16
precision: 1
unit_of_measurement: V
device_class: Voltage
state_class: measurement
scale: 0.1
scan_interval: 60
- name: L3 Grid Freq
unique_id: l3_grid_freq
device_address: 3
address: 16449
input_type: input
data_type: uint16
precision: 2
unit_of_measurement: Hz
device_class: Frequency
state_class: measurement
scale: 0.01
scan_interval: 60
- name: L3 Grid DCI
unique_id: l3_grid_dci
device_address: 3
address: 164450
input_type: input
data_type: int16
precision: 2
unit_of_measurement: A
device_class: Current
state_class: measurement
scale: 1000
scan_interval: 60
Me again 😆
It should be possible to get information about the energy consumed from public grid or sent to grid as these devices get delivered with an energy meter connected to the inverter. I can see the values in the AMPERE HOME App so the values are available.
Unfortunately I don't know how to get the values from modbus to find them on my own :( I'll try and see if I can find them on iQ at least