Open lanshuyue opened 5 hours ago
The software unexpectedly crashes when performing a SCF calculation of oxygen crystal system.
No response
STRU:(mp_12957)
ATOMIC_SPECIES O 15.999 O_ONCV_PBE-1.0.upf NUMERICAL_ORBITAL O_gga_10au_100Ry_2s2p1d.orb LATTICE_CONSTANT 1.8897261258369282 LATTICE_VECTORS 3.3463770000 0.0000000000 0.0000000000 -1.673188000 2.8980470000 0.0000000000 0.0000000000 0.0000000000 11.205553000 ATOMIC_POSITIONS Direct O 0.0000000000 6 0.0000000000 0.0000000000 0.0550460000 1 1 1 mag 0.0 0.0000000000 0.0000000000 0.9449540000 1 1 1 mag 0.0 0.6666670000 0.3333330000 0.3883790000 1 1 1 mag 0.0 0.6666670000 0.3333330000 0.2782880000 1 1 1 mag 0.0 0.3333330000 0.6666670000 0.7217120000 1 1 1 mag 0.0 0.3333330000 0.6666670000 0.6116210000 1 1 1 mag 0.0
INPUT:
INPUT_PARAMETERS #Parameters (1.General) suffix O2 calculation scf ntype 1 symmetry 1 pseudo_dir ./ #Parameters (2.Iteration) ecutwfc 100 scf_nmax 100 #Parameters (3.Basis) basis_type lcao #Parameters (4.Smearing) smearing_method mp smearing_sigma 0.0036 #Parameters (5.Mixing) mixing_type broyden mixing_beta 0.7
KPT:
K_POINTS 0 Gamma 9 9 9 0 0 0
abacus3.5.3
@YuLiu98 could you have a look?
Hi @lanshuyue , you can retry this calculation using abacus v3.8.0, which I tested successfully.
Describe the bug
The software unexpectedly crashes when performing a SCF calculation of oxygen crystal system.
Expected behavior
No response
To Reproduce
STRU:(mp_12957)
INPUT:
KPT:
Environment
abacus3.5.3
Additional Context
No response
Task list for Issue attackers (only for developers)