Rev B of the main board moved the footswitch connector from a panel-mount jack to a PCB-mount jack on the edge of the board.

This seemed like a good idea in theory, but in practice it makes it impossible to actually install the PCB into the updated L-shaped enclosure design.

Thus, we need to go back to the old design, which most likely means putting a 2-pin JST PH style connector on the main PCB, and connecting a panel-mount footswitch connector via a pigtail wire.