Shouldnt all 2-min cadence TOIs have SPOC parameter estimates? #237

Closed avivajpeyi closed 2 years ago

avivajpeyi commented 2 years ago

The ExoFOP TOI list has a column with "Source", that specifies the pipeline used to generate the parameter estimates provided. There are quite a few of these:

Pipelines

Pipeline -- alert with qlp-s33-faintsearch qlp qlp-CTOIs qlp-s01s02 qlp-s04-b01 qlp-s04-b02 qlp-s05-b01 qlp-s07-ffi qlp-s08-b03b qlp-s09-b03 qlp-s09-ffi qlp-s11-beta-cam3 qlp-s12-ffi qlp-s13-ffi qlp-s14-ffi qlp-s16-ffi_s qlp-s20-faintsearch qlp-s20-ffi qlp-s21-faintsearch qlp-s23-faintsearch qlp-s25-faintsearch qlp-s25-ffi qlp-s26-faintsearch qlp-s27-466206508 qlp-s27-ffi qlp-s28-faintsearch qlp-s28-ffi qlp-s28-tois qlp-s29-faintsearch qlp-s29-ffi qlp-s29-tois qlp-s30-ffi qlp-s31-257527578 qlp-s31-faintsearch qlp-s31-ffi qlp-s31-tois qlp-s32-faintsearch qlp-s32-ffi qlp-s32-tois qlp-s33-124029677 qlp-s33-faintsearch qlp-s34-faintsearch qlp-s35-332564140 qlp-s35-faintsearch qlp-s36-179230828 qlp-s36-faintsearch qlp-s36-ffi qlp-s36-tois qlp-s37-231721006 qlp-s37-faintsearch qlp-s37-tois qlp-s38-faintsearch qlp-s38-ffi qlp-s38-tois qlp-s39-291517604 qlp-s39-388130237 qlp-s39-faintsearch qlp-s39-tois qlp-s40-faintsearch qlp-s40-tois qlp-s41-286094277 qlp-s41-40954422 qlp-s41-7583660 qlp-s41-faintsearch qlp-s41-ffi qlp-s41-tois qlp-s42-240849748 qlp-s42-faintsearch qlp-s42-ffi qlp-s42-tois qlp-s43-388811663 qlp-s43-faintsearch qlp-s43-tois qlp-s44-268143410 qlp-s44-faintsearch qlp-s44-ffi qlp-s44-reprocessed qlp-s44-tois qlp-s45-97669493 qlp-s45-faintsearch qlp-s45-ffi qlp-s45-reprocessed qlp-s45-tois qlp-s46-faintsearch qlp-s46-ffi qlp-s46-reprocessed qlp-s46-tois qlp-s47-456305193 qlp-s47-faintsearch qlp-s47-ffi qlp-s47-tois qlp-s48-faintsearch qlp-s48-ffi qlp-s48-tois qlp-s49-ffi qlp-s50-ffi qlp-toi-update-03-29-22 qlp-tois-update sector-01-qlp-alerts sector-01-spoc-alerts spoc spoc-s01-46-b0A spoc-s01-s36-b02-L1 spoc-s01-s36-b0A spoc-s01-s36-b0A-CPKP spoc-s01-s36-b0A-PC spoc-s01-s39-b02-vetted spoc-s01-s39-b0A spoc-s01-s39-b0A-CP spoc-s01-s39-b0A-KP spoc-s01-s39-b0A-PC spoc-s01-s46-b02 spoc-s01-s46-b0A spoc-s01-s46-b0H spoc-s01s06-b0A spoc-s01s13-b0A spoc-s03-b01 spoc-s03-b02 spoc-s04-b03 spoc-s05-b02_old spoc-s06-b01 spoc-s07-b01 spoc-s08-b01 spoc-s09-b01 spoc-s13-b02 spoc-s14-b02 spoc-s14-s41-b0A-APC spoc-s14-s41-b0A-CP spoc-s14-s41-b0A-KP spoc-s14-s41-b0A-PC spoc-s14s16-b02 spoc-s14s19-b02-reprocessed-new spoc-s14s23-b02 spoc-s14s26-b02 spoc-s14s26-b0H spoc-s18-tier3 spoc-s20-b02 spoc-s22-b02 spoc-s23-b02 spoc-s28-b0A spoc-s41-b0A spoc-s42-b02 spoc-s42-b0A spoc-s42-s43 spoc-s42-s43-b0A spoc-s42-s46-b02 spoc-s42-s46-b0H spoc-s44-b02 spoc-s44-b0A spoc-s45-b02 spoc-s45-b0A spoc-s46-b02 spoc-s46-b0A spoc-s47-b02 spoc-s47-b0A spoc-s48-b02 spoc-s48-b0A spoc-s50-b0A

However I think these boil down to:

The TESS Prime paper mentions that if a TOI has been fit with both QLP + SPOC, the SPOC estimate is preferred (as it uses 2-min cadence data)

However, we see that: Sources for TOIs with 2-min cadence data: {'qlp': 1277, 'spoc': 1749}

Shouldnt all the TOIs with 2-min cadence data have source params from SPOC?

avivajpeyi commented 2 years ago

Na Dan suggested that makes sense -- QLP may have just found some that were not considered planet candidates by SPOC. However, SPOC did manage to make lightcurves for these.