diyless / opentherm-thermostat2

OpenTherm Thermostat2 examples and feedback repo
1 stars 0 forks source link

Boiler control only partly working #1

Open devinfluencer opened 2 months ago

devinfluencer commented 2 months ago

Hi I have an old OT Boiler from the 2002 timeframe (OT maybe ver 2.0). It is made by Remeha and OEM labelled by Windhager. Contrl of the device is not working correctly, the only reaction I got was the hot water temperature display seemed right and shutting of water heating via WIFI worked. The room temperature seemed not to be sent to the boiled, as it displayed "sensor broken" and began to permanently heat the room. The boiler uses a room temp. of 0 in case the sensor is broken according to the manual. Shutting off heating via WIFI did not work. Do you think settign the member ID to 11 for Remeha might improve the situation?

diyless commented 1 month ago

Hi @devinfluencer , The Thermostat2 is compatible with all OpenTherm versions, you can try to set member id. In general, the thermostat should not send the room temperature to the boiler. It calculates the boiler setpoint based on the target and actual room temperature. Why do you have "sensor broken"? Do you have the BLE sensor configured as a room sensor or another option?

devinfluencer commented 1 month ago

Hi diyless, I didn't know that about the room temerature. Thanks. In the meantime I found out some more things:

Thomas