Closed GoogleCodeExporter closed 9 years ago
Reading the mode switch is the primary exit from a long failsafe condition.
Once a long failsafe is established due to loss of signal the failsafe is not
cleared when the RX signal is again received as this also presents a crash risk
as the user will not know exactly when this will happen and may be unprepared.
Receivers (generally) continue to output the last value, in which case there is
no toggling of mode possible, or can be programmed to output a particular
value. In the latter case the user should program the mode channel failsafe to
something sensible like RTL.
Original comment by dewei...@gmail.com
on 12 Sep 2011 at 1:16
Original issue reported on code.google.com by
justinbe...@gmail.com
on 5 Sep 2011 at 2:26