Solar Financial Model #296

Closed drdanley closed 9 years ago

drdanley commented 9 years ago

Tried running solar financial model for KY with 1390 kW-DC array at $2,500,000 with $20,000 maintenance. Tilt=lat = false. Manual tilt = 25. All other values using program default.

When [Run Model] button is clicked, program gives the following error: "Internal Server Error

The server encountered an internal error and was unable to complete your request. Either the server is overloaded or there is an error in the application."

I need to be able to run the program to evaluate the outputs and to try various combinations of system design to test program for veracity.

mannanj commented 9 years ago

Solar financial was made more crash resistance and made error text show up in web error section. Almost all Davids effort.

One of the problems with running the model with the above values was the model requires an input for SREC but was not checking for it. It is now filled by default to '0'.

dpinney commented 9 years ago

Fix is in production.