Open SwoopX opened 3 years ago
Pick up the channel change issue for higher channels from here https://github.com/dresden-elektronik/deconz-rest-plugin/issues/4005#issuecomment-750582124
Tested in my test environment. Previous channel was 15. Going down to 11 was ok, going up to 20 resulted in a failed channel change (25 untested, but same expected).
This guidance does NOT succeed: https://github.com/dresden-elektronik/deconz-rest-plugin/issues/4005#issuecomment-750399933
Change channel from 11 to 20 (regardless if Phoscon or deconz GUI).
Channel change to be successful and also applied to the coordinator.
My observations:
FYI: Upgrade to FW 26400500 without channel change still works. (CH 25 for me) But i will not touch the channel to test if the switch works again. ;-)
Describe the bug
Pick up the channel change issue for higher channels from here https://github.com/dresden-elektronik/deconz-rest-plugin/issues/4005#issuecomment-750582124
Tested in my test environment. Previous channel was 15. Going down to 11 was ok, going up to 20 resulted in a failed channel change (25 untested, but same expected).
This guidance does NOT succeed: https://github.com/dresden-elektronik/deconz-rest-plugin/issues/4005#issuecomment-750399933
Steps to reproduce the behavior
Change channel from 11 to 20 (regardless if Phoscon or deconz GUI).
Expected behavior
Channel change to be successful and also applied to the coordinator.
Screenshots
Environment
deCONZ Logs
Additional context
My observations: