Hi, is there a quick way to get the basics (thermometer read-out, temperature set, and valve setting) of the thermostat working?
Yes, take a working DDF and just set your model id and manufacture name. If the device respect standard it will work direclty, after can need adjustement. As sample you can take this one https://github.com/dresden-elektronik/deconz-rest-plugin/blob/master/devices/elko/thermostat_16_a.json But need to remove TYPE_CONSUMPTION_SENSOR
thanks! the thermostat is now working perfectly.
And I was wrong, you can keep the TYPE_CONSUMPTION_SENSOR. But Now I m looking better the DDF, but was same device ? It use the TYPE_CONSUMPTION_SENSOR on same endpoint than your, the 0x05 ....
Is there already an existing issue for this?
Product name
Connected Raumtemperaturregler- Modul, polarweiss, System M, ZB
Manufacturer
Schneider Electric
Model identifier
MEG5779
Device type to add
Thermostat
Node info
Endpoints and clusters
Basic
Further relevant clusters
Power Configuration
On/Off
Level Control
Color Control
Thermostat
Thermostat User Interface Configuration Cluster
02 Home Automation Temperature Sensor - Basic
02 Home Automation Temperature Sensor - Temperature Measurement
04 Home Automation Occupancy sensor - Basic
04 Home Automation Occupancy sensor - Occupancy sensing
05 Home Automation Consumption Awareness Device - Basic
05 Home Automation Consumption Awareness Device - 0702 Simple Metering
Simple Metering
Electrical Measurement
Any other cluster of relevance/interest