Closed JanMisker closed 6 months ago
This is a device installed on the DIN Rail. I can use it to switch On/Off, that works fine. But I am interested to also read the power consumption. When using the REST API I don't see it reported (I guess it should be a subdevice?).
I use homebridge-deconz to bridge deCONZ into my Homebridge/HomeKit setup.
I did some digging and figured out how to use the DFF editor. I now get readout in Homebridge/HomeKit so seems to do the trick :)
I am now wondering whether the Current Summation Delivered
from the Simple Metering is not shown in kWh but with some multiplier. Does someone know what exactly kW & kWh Binary
means in the Unit of Measure
?
As there has not been any response in 21 days, this issue has been automatically marked as stale. At OP: Please either close this issue or keep it active It will be closed in 7 days if no further activity occurs.
Not sure if I need to do something else to get this merged?
As there has not been any response in 21 days, this issue has been automatically marked as stale. At OP: Please either close this issue or keep it active It will be closed in 7 days if no further activity occurs.
As there has not been any response in 28 days, this issue will be closed. @ OP: If this issue is solved post what fixed it for you. If it is not solved, request to get this opened again.
Is there already an existing issue for this?
Product name
Gledopto GL-DR-001Z DIN Rail ZigBee Circuit Breaker
Manufacturer
_TZ3000_zwtj16m9
Model identifier
TS011F
Device type to add
Switch
Node info
Endpoints and clusters
Basic
Further relevant clusters
On/Off
Simple Metering
Electrical Measurement
This is the one I'm actually most interested in. Almost all attribute rows are greyed out, except these 3.
With a load on it I could see (also based on overall watt used) that
0x0508 RMS Current
is shown in mA, so for example it shows6600
for 6.6 Ampere and0x050B Active Power
is in Watt, so for the 6600 (mA) it showed1500
(W).Any other cluster of relevance/interest