dresden-elektronik / phoscon-app-beta

Access to Phoscon app beta
79 stars 5 forks source link

Unable to integrate a Philips Motion Sensor SML001 #432

Closed ConnOnGit closed 2 years ago

ConnOnGit commented 2 years ago

When I try to add a Philips Motion Sensor SML001 using the interface, the sensor is supposed to be as not reachable. There could no data been read from the sensor (temperature & light level) instead of the adress and the firmware. I'm using the Raspee gateway version 2.13.01 / 6.10.2021 and the firmware 26400500.

I already tried another SML001 sensor- same behavior. The motion sensor is fully recognized with the Philips bridge and app.

The phoscon API information says: { "71": { "config": { "alert": "none", "battery": null, "delay": 0, "ledindication": false, "on": true, "pending": [], "reachable": true, "sensitivity": 2, "sensitivitymax": 2, "usertest": false }, "ep": 2, "etag": "aeb434c862ca9d9737e0a3cdfb5fd3d5", "lastannounced": null, "lastseen": "2021-11-02T08:45Z", "manufacturername": "Philips", "modelid": "SML001", "name": "Bewegungsmelder", "state": { "lastupdated": "none", "presence": false }, "swversion": "6.1.1.27575", "type": "ZHAPresence", "uniqueid": "00:17:88:01:02:03:9d:4f-02-0406" }, "72": { "config": { "alert": "none", "battery": null, "ledindication": false, "offset": 0, "on": true, "pending": [], "reachable": true, "usertest": false }, "ep": 2, "etag": "339f8d8f7bd61dd47991e77763f7f6db", "lastannounced": null, "lastseen": "2021-11-02T08:15Z", "manufacturername": "Philips", "modelid": "SML001", "name": "Temperature 72", "state": { "lastupdated": "none", "temperature": null }, "swversion": "6.1.1.27575", "type": "ZHATemperature", "uniqueid": "00:17:88:01:02:03:9d:4f-02-0402" }, "73": { "config": { "alert": "none", "battery": null, "ledindication": false, "on": true, "pending": [], "reachable": true, "tholddark": 12000, "tholdoffset": 7000, "usertest": false }, "ep": 2, "etag": "339f8d8f7bd61dd47991e77763f7f6db", "lastannounced": null, "lastseen": "2021-11-02T08:15Z", "manufacturername": "Philips", "modelid": "SML001", "name": "LightLevel 73", "state": { "dark": null, "daylight": null, "lastupdated": "none", "lightlevel": null, "lux": null }, "swversion": "6.1.1.27575", "type": "ZHALightLevel", "uniqueid": "00:17:88:01:02:03:9d:4f-02-0400" } }

Any help is highly appreciated!

hAMMERlized commented 2 years ago

Had the same issue. So I've deleted the Sensor and reconnected it at the sensor menu but chosen "Others" not "Philips". Sensor got detected instantly and after a few seconds the Lux and Temperatur values plopped in. Hope this will help.

stale[bot] commented 2 years ago

As there hasn't been any response in 21 days, this issue has been automatically marked as stale. At OP: Please either close this issue or keep it active It will be closed in 7 days if no further activity occurs.

stale[bot] commented 2 years ago

As there hasn't been any response in 28 days, this issue will be closed. @ OP: If this issue is solved post what fixed it for you. If it isn't solved, request to get this opened again.