eLvErDe / hwraid

HWRaid: Free code from http://hwraid.le-vert.net
GNU General Public License v2.0
273 stars 103 forks source link

sas2ircu-status It shows abnormal state array #42

Open LordMerlin opened 8 years ago

LordMerlin commented 8 years ago

1.

root@pve1:~# sas2ircu list
LSI Corporation SAS2 IR Configuration Utility.
Version 20.00.00.00 (2014.09.18)
Copyright (c) 2008-2014 LSI Corporation. All rights reserved.

         Adapter      Vendor  Device                       SubSys  SubSys
 Index    Type          ID      ID    Pci Address          Ven ID  Dev ID
 -----  ------------  ------  ------  -----------------    ------  ------
   0     SAS2004     1000h    70h   00h:01h:00h:00h      1000h   3010h
SAS2IRCU: Utility Completed Successfully.

2.

root@pve1:~# sas2ircu 0 DISPLAY
LSI Corporation SAS2 IR Configuration Utility.
Version 20.00.00.00 (2014.09.18)
Copyright (c) 2008-2014 LSI Corporation. All rights reserved.
Read configuration has been initiated for controller 0
------------------------------------------------------------------------
Controller information
------------------------------------------------------------------------
  Controller type                         : SAS2004
  BIOS version                            : 7.39.02.00
  Firmware version                        : 20.00.07.00
  Channel description                     : 1 Serial Attached SCSI
  Initiator ID                            : 0
  Maximum physical devices                : 255
  Concurrent commands supported           : 1720
  Slot                                    : 10
  Segment                                 : 0
  Bus                                     : 1
  Device                                  : 0
  Function                                : 0
  RAID Support                            : Yes
------------------------------------------------------------------------
IR Volume information
------------------------------------------------------------------------
IR volume 1
  Volume ID                               : 286
  Status of volume                        : Okay (OKY)
  Volume wwid                             : 03b1af2ecb4eb1ec
  RAID level                              : RAID10
  Size (in MB)                            : 278472
  Physical hard disks                     :
  PHY[0] Enclosure#/Slot#                 : 2:0
  PHY[1] Enclosure#/Slot#                 : 2:1
  PHY[2] Enclosure#/Slot#                 : 2:2
  PHY[3] Enclosure#/Slot#                 : 2:3
------------------------------------------------------------------------
Physical device information
------------------------------------------------------------------------
Initiator at ID #0

Device is a Enclosure services device
  Enclosure #                             : 2
  Slot #                                  : 0
  SAS Address                             : 5000e0c-e-36b1-200b
  State                                   : Standby (SBY)
  Manufacturer                            : ESG-SHV.
  Model Number                            : SCA HSBP M1.....
  Firmware Revision                       : 2.17
  Serial No                               : ESGSHVqa217
  GUID                                    : N/A
  Protocol                                : SAS
  Device Type                             : Enclosure services device

Device is a Hard disk
  Enclosure #                             : 2
  Slot #                                  : 0
  SAS Address                             : 5000cca-0-1121-ea39
  State                                   : Optimal (OPT)
  Size (in MB)/(in sectors)               : 140205/287140276
  Manufacturer                            : HITACHI
  Model Number                            : HUS153014VLS300
  Firmware Revision                       : A410
  Serial No                               : JNVLN6LC
  GUID                                    : 5000cca01121ea38
  Protocol                                : SAS
  Drive Type                              : SAS_HDD

Device is a Hard disk
  Enclosure #                             : 2
  Slot #                                  : 1
  SAS Address                             : 5000cca-0-1123-4ae5
  State                                   : Optimal (OPT)
  Size (in MB)/(in sectors)               : 140205/287140276
  Manufacturer                            : HITACHI
  Model Number                            : HUS153014VLS300
  Firmware Revision                       : A410
  Serial No                               : JNVMDPPC
  GUID                                    : 5000cca011234ae4
  Protocol                                : SAS
  Drive Type                              : SAS_HDD

Device is a Hard disk
  Enclosure #                             : 2
  Slot #                                  : 2
  SAS Address                             : 5000cca-0-1123-4d75
  State                                   : Optimal (OPT)
  Size (in MB)/(in sectors)               : 140205/287140276
  Manufacturer                            : HITACHI
  Model Number                            : HUS153014VLS300
  Firmware Revision                       : A410
  Serial No                               : JNVMDVZC
  GUID                                    : 5000cca011234d74
  Protocol                                : SAS
  Drive Type                              : SAS_HDD

Device is a Hard disk
  Enclosure #                             : 2
  Slot #                                  : 3
  SAS Address                             : 5000cca-0-1126-c97d
  State                                   : Optimal (OPT)
  Size (in MB)/(in sectors)               : 140205/287140276
  Manufacturer                            : HITACHI
  Model Number                            : HUS153014VLS300
  Firmware Revision                       : A410
  Serial No                               : JNVPA8LC
  GUID                                    : 5000cca01126c97c
  Protocol                                : SAS
  Drive Type                              : SAS_HDD

Device is a Hard disk
  Enclosure #                             : 2
  Slot #                                  : 4
  SAS Address                             : 5000cca-0-1121-7f45
  State                                   : Hot Spare (HSP)
  Size (in MB)/(in sectors)               : 140205/287140276
  Manufacturer                            : HITACHI
  Model Number                            : HUS153014VLS300
  Firmware Revision                       : A410
  Serial No                               : JNVLE2TC
  GUID                                    : 5000cca011217f44
  Protocol                                : SAS
  Drive Type                              : SAS_HDD
------------------------------------------------------------------------
Enclosure information
------------------------------------------------------------------------
  Enclosure#                              : 1
  Logical ID                              : 500062b0:002e2b80
  Numslots                                : 4
  StartSlot                               : 0
  Enclosure#                              : 2
  Logical ID                              : 5000e0ce:36b12000
  Numslots                                : 9
  StartSlot                               : 0
------------------------------------------------------------------------
SAS2IRCU: Command DISPLAY Completed Successfully.
SAS2IRCU: Utility Completed Successfully.

3.

sas2ircu 0 STATUS
LSI Corporation SAS2 IR Configuration Utility.
Version 20.00.00.00 (2014.09.18)
Copyright (c) 2008-2014 LSI Corporation. All rights reserved.

Background command progress status for controller 0...
IR Volume 1
  Volume ID                               : 286
  Current operation                       : None
  Volume status                           : Enabled
  Volume state                            : Optimal
  Volume wwid                             : 03b1af2ecb4eb1ec
  Physical disk I/Os                      : Not quiesced
SAS2IRCU: Command STATUS Completed Successfully.
SAS2IRCU: Utility Completed Successfully.

4.

root@pve1:~# sas2ircu-status
-- Controller informations --
-- ID | Model
c0 | SAS2004

-- Arrays informations --
-- ID | Type | Size | Status
c0u0 | RAID10 | 278G | Okay (OKY)

-- Disks informations
-- ID | Model | Status
c0u0p0 | SCA HSBP M1..... (ESGSHVqa217) | Standby (SBY)
c0u0p1 | HUS153014VLS300 (JNVLN6LC) | Optimal (OPT)
c0u0p2 | HUS153014VLS300 (JNVMDPPC) | Optimal (OPT)
c0u0p3 | HUS153014VLS300 (JNVMDVZC) | Optimal (OPT)
c0u0p4 | HUS153014VLS300 (JNVPA8LC) | Optimal (OPT)

There is at least one disk/array in a NOT OPTIMAL state.

As you can see, the presence of a hot spare, but the script sas2ircu-status it does not show, and gives incorrect status of the array.

LordMerlin commented 6 years ago

Please help with the script, where you need to correct that it worked correctly.

LordMerlin commented 4 years ago

UP