Closed foprs closed 6 months ago
I feel it is a misunderstanding: up to now there is exactly one data spec, the IEC 61360 data specification. In former versions there was a second one for physical units but in V3.0 it is not valid any longer.
A concept description never is a correct data specification reference. Please just click the "Add IEC61369" Button to see how it should look like.
Here more information regarding the issue
I am opening Technical_Data_LGM_v2.aasx (see atachment, attached as .zip, because GitHub is not accepting .aasx) with PE 2, DataSpecification is shown
I am opening same file (Technical_Data_LGM_v2.aasx) with PE 3, DataSpecification is not shown, But the unit is shown at the property in the tree, which means that the unit is added here correct but the DataSpecification is not shown correctly
PE2:
PE 3:
Hi @foprs ,
Thank you for raising the issue !!
The issue has been reproduced and we are working on it. We will keep you informed once it is fixed.
After loading the aasx-file that has been create with an ealier version into PE 3, the DataSpec. is not shown anymore. The unit is shown at the property submodel element. That means the information is still existing.
Technical_Data_LGM_v2.zip