Growatt SPF 5000 ES Missing Data #51

Open julianjosias opened 9 months ago

julianjosias commented 9 months ago

Hi Legends,

I have this all setup however, there is missing data. I have set spf in inverter type on the Grott ini. Forgive me for my lack of knowledge as I am a total noob. Capture PNG3 Capture PNG4 Capture Capture PNG1 Capture PNG2

egguy commented 8 months ago

Hi, how did you configure the SPH parameter? Did you use the interface? or created a file?

yvesdemoerloose commented 8 months ago

I had a similar problem but noticed I wrongly used sph in the config instead of spf, changing that fixed the Unknown problem. I do miss some sensors, for example import from grid today/total. Is there anyway to get this, or should data be put in a local database to archieve that (I guess...) Any info or howto's on that? Also the correct config entries for the home assistant energy dashboard would be very welcome. Thx

julianjosias commented 8 months ago

Hi egguy. I used the interface grott ini spf (not sph).

github-actions[bot] commented 7 months ago

There hasn't been any activity on this issue recently, so we clean up some of the older and inactive issues. Please make sure to update to the latest version and check if that solves the issue. Let us know if that works for you by leaving a comment šŸ‘ This issue has now been marked as stale and will be closed if no further activity occurs. Thanks!

julianjosias commented 6 months ago

Just bumping this egguy.

irpyc commented 5 months ago

Hi, I also installed this addon, IĀ“m so thankful for it, the terrible Growatt app is one of the main reason why I begun my HA journey huhu. Thanks a lot for all the work.

But I also have some missing value for my system (SPF 5000, with Pylontech battery). The most annoying ones are the fact I donĀ“t have a "Battery charge from Solar today". The only information about charge is the "Battery discharge power" showing negative value.

Therefor I cannot integrate it in the HA "Energy" Tab :( I already spent hours trying to find a workaround...

Also I didnĀ“t found values differentiating Power generated from Power in Bypass mode, but IĀ“m not that far in my configuration.

Some screenshot (not that much sun today, and the inverter is still in Bypass mode, since it start at 30%)