PIXm Query: the targetSystem should be both the MPI-PID and the EPR-SPID #112

Closed qligier closed 6 months ago

qligier commented 6 months ago

In https://fhir.ch/ig/ch-epr-mhealth/iti-83.html:

targetSystem 1..2 [...] SHALL be Restricted to the Assigning authority of the community and/or the EPR-SPID.

Amendment 1 of Annex 5 EPRO-FDHA says: (§1.8.1.1, p36)

The DataSource Parameter SHALL be specified to the assigning authorities of the EPR-SPID and the MPI-PID in the affinity domain.

The targetSystem should be 2..2 and the and/or should be simplified to and.