  • [x] It is probably bug in documentation but it says that, 4th pin is drain referenced to 3.3V instead of 1.8V, so it should be verified.

Checked. It is a bug in documentation.

  • [x] consider higher voltage rate of C5, 50V is close to working voltage.

Changed to CC0805_1UF_100V_10%_X7S

  • [ ] vias are unmasked, is it on purpose?

I was using vias parameters from a previous project: https://github.com/elhep/SIQCI_ASIC_test_adapter

  • [x] Unconnected via

Fixed

  • [x] missing outjob file

Added

filipswit commented 2 months ago