Open filipswit opened 3 months ago
- [x] It is probably bug in documentation but it says that, 4th pin is drain referenced to 3.3V instead of 1.8V, so it should be verified.
Checked. It is a bug in documentation.
- [x] consider higher voltage rate of C5, 50V is close to working voltage.
Changed to CC0805_1UF_100V_10%_X7S
- [ ] vias are unmasked, is it on purpose?
I was using vias parameters from a previous project: https://github.com/elhep/SIQCI_ASIC_test_adapter
- [x] Unconnected via
Fixed
- [x] missing outjob file
Added
[x] It is probably bug in documentation but it says that, 4th pin is drain referenced to 3.3V instead of 1.8V, so it should be verified.
[x] consider higher voltage rate of C5, 50V is close to working voltage.
[x] vias are unmasked, is it on purpose?
[x] Unconnected via
[x] missing outjob file