epam / ketcher

Web-based molecule sketcher
https://lifescience.opensource.epam.com/ketcher/demo.html
Apache License 2.0
472 stars 164 forks source link

Macro: System marks availiable connection point as unavaliable in Select Connection Point dialog #3736

Closed AlexeyGirin closed 8 months ago

AlexeyGirin commented 9 months ago

Issue found in the context of testing #3580

Steps to Reproduce

  1. Switch to Macromolecules view
  2. Load this file: ConnectionDialogTests.zip (unzip first)
  3. Connect R3 connection point of H peptide with center of M peptide image Select connection dialog appears - this is ok.
  4. Click on R2 connection point for Histidine

Actual behavior Note that system removes selection from R3 connection point on preview, but paint it as unavailable for connection (already connected) image Same problem in expanded mode

Expected behavior System removes selection from R3 connection point on preview and paint it as available for connection

Desktop (please complete the following information):

Ketcher version [e.g. v2.4.2]. image

AlexeyGirin commented 9 months ago

No fixed. image

Ketcher Version 2.17.0-rc.2 Build at 2024-01-03; 14:08:44 Feedback EPAM Life Sciences

Indigo Toolkit Version 1.17.0-rc.3.0-g1a7f60990-wasm32-wasm-clang-12.0.0

Zhirnoff commented 9 months ago

Test added to the automation table.

Zhirnoff commented 7 months ago

Tested. Fixed. 2024-02-21_11h55_56