Closed erebuslabs closed 9 years ago
Great I will look into these, their associated circuits, outputs and sourcing, I will look into it but off the top: are they only available through figaro or are they simply the mfg?
...and which gases? Methane? O2? CO2?
Let's go with Methane with a backup of CO2 (if that's not feasible). Also since the Figaro's might be hard to come across in short time spans - you can also consider Parralax sensors available from digikey.
How is the acquisition of sensors going? Need any additional help from my end?
We do not currently have a VOC picked out, we have designed the sensor boards around "any" analog type sensor so the VOC would just be dropped/soldered in, then the values handled in software. If you would like to have us implement one specifically could you order at least 2 and have them sent to PSU c/o Dr. Zurk?
Steve Peirce CTO Eulerworks Inc. 503-519-4846
On Mar 23, 2015, at 12:58 PM, Mike@ Erebus Labs notifications@github.com wrote:
How is the acquisition of sensors going? Need any additional help from my end?
— Reply to this email directly or view it on GitHub.
Done. N=2 605-00008-ND Methane Gas Sensors Ordered and being shipped to
Dr. Zurk @ Portland State Univ. ECE Dept 160-17 FAB 1900 SW Fourth Portland, OR 97207 USA
Salesorder Number: 42505064
Here is the tracking link Should be delivered to the university today (from there don't know how long it will take to get into Dr. Zurk's hands)
Great, thank you. Looks like they were delivered today.
Steve Peirce CTO Eulerworks Inc. 503-519-4846
On Mar 23, 2015, at 1:28 PM, Mike@ Erebus Labs notifications@github.com wrote:
Done. N=2 605-00008-ND Methane Gas Sensors Ordered and being shipped to
Dr. Zurk @ Portland State Univ. ECE Dept 160-17 FAB 1900 SW Fourth Portland, OR 97207 USA
Salesorder Number: 42505064
— Reply to this email directly or view it on GitHub.
Team is looking for details surrounding the VOCs to detect as well as sensor type: