Closed bobfh closed 1 year ago
Hello,
Try with bg.dt.x.isl protocol.
2023-08-09 17:51:00 INF] Starting the service, version 1.1.0.721... [ 2023-08-09 17:51:00 INF] Autodetecting local printers... [ 2023-08-09 17:51:00 INF] Probing (1/9)bg.dt.x.isl.com://COM8... [ 2023-08-09 17:51:01 INF] COM8 <<< 01-30-30-32-3B-21-30-30-35-3A-31-05-30-31-3F-33-03 [ 2023-08-09 17:51:01 INF] Keep Alive Background Service is started. [ 2023-08-09 17:51:01 INF] Opening the com port COM8 [ 2023-08-09 17:51:01 INF] COM8 >>> 16-01-30-30-36-3A-21-30-30-35-3A-44-50-2D-31-35-30-4D-58-2C-36-30-39-34-32-38-20-32-30-4A-75-6C-32-33-20-31-33-35-33-2C-39-34-36-30-2C-30-30-30-30-30-30-30-30-2C-20-20-20-20-30-32-35-30-30-30-30-32-04-80-80-80-80-84-82-80-80-05-31-31-31-32-03 [ 2023-08-09 17:51:01 INF] Device at COM8 incompatible with protocol bg.dt.x.isl: invalid device info returned. [ 2023-08-09 17:51:01 INF] Probing (2/9)bg.dt.c.isl.com://COM8... [ 2023-08-09 17:51:01 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 17:51:01 INF] Com port COM8 allready opened! [ 2023-08-09 17:51:01 INF] COM8 >>> 16 [ 2023-08-09 17:51:01 INF] COM8 >>> 15 [ 2023-08-09 17:51:01 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 17:51:01 INF] Com port COM8 allready opened! [ 2023-08-09 17:51:01 INF] COM8 >>> 16 [ 2023-08-09 17:51:01 INF] COM8 >>> 15 [ 2023-08-09 17:51:01 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 17:51:01 INF] Com port COM8 allready opened! [ 2023-08-09 17:51:01 INF] COM8 >>> 16 [ 2023-08-09 17:51:01 INF] COM8 >>> 15 [ 2023-08-09 17:51:01 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 17:51:01 INF] Com port COM8 allready opened! [ 2023-08-09 17:51:01 INF] COM8 >>> 16 [ 2023-08-09 17:51:01 INF] COM8 >>> 15 [ 2023-08-09 17:51:01 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 17:51:01 INF] Com port COM8 allready opened! [ 2023-08-09 17:51:01 INF] COM8 >>> 16 [ 2023-08-09 17:51:01 INF] COM8 >>> 15 [ 2023-08-09 17:51:01 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 17:51:01 INF] Com port COM8 allready opened! [ 2023-08-09 17:51:01 INF] COM8 >>> 16 [ 2023-08-09 17:51:01 INF] COM8 >>> 15 [ 2023-08-09 17:51:01 INF] Device at COM8 incompatible with protocol bg.dt.c.isl: invalid device info returned. [ 2023-08-09 17:51:01 INF] Probing (3/9)bg.dt.p.isl.com://COM8... [ 2023-08-09 17:51:01 INF] Device at COM8 incompatible with protocol bg.dt.p.isl: invalid device info returned. [ 2023-08-09 17:51:01 INF] Probing (4/9)bg.ed.isl.com://COM8... [ 2023-08-09 17:51:01 INF] Device at COM8 incompatible with protocol bg.ed.isl: invalid device info returned. [ 2023-08-09 17:51:01 INF] Probing (5/9)bg.dy.isl.com://COM8... [ 2023-08-09 17:51:01 INF] Device at COM8 incompatible with protocol bg.dy.isl: invalid device info returned. [ 2023-08-09 17:51:01 INF] Probing (6/9)bg.in.isl.com://COM8... [ 2023-08-09 17:51:01 INF] Device at COM8 incompatible with protocol bg.in.isl: invalid device info returned. [ 2023-08-09 17:51:01 INF] Probing (7/9)bg.is.icp.com://COM8... [ 2023-08-09 17:51:01 INF] COM8 <<< 02-30-30-30-30-30-30-30-3C-38-3E-03 [ 2023-08-09 17:51:01 INF] Com port COM8 allready opened! [ 2023-08-09 17:51:02 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 17:51:02 INF] COM8 Cannot read from channel: Timeout occured while reading from com port 'COM8' [ 2023-08-09 17:51:02 INF] Device at COM8 incompatible with protocol bg.is.icp: invalid device info returned. [ 2023-08-09 17:51:02 INF] Probing (8/9)bg.zk.zfp.com://COM8... [ 2023-08-09 17:51:02 INF] COM8 <<< Ping: 9 [ 2023-08-09 17:51:02 INF] Opening the com port COM8 [ 2023-08-09 17:51:03 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 17:51:03 INF] Timeout, try again! [ 2023-08-09 17:51:03 INF] COM8 <<< Ping: 9 [ 2023-08-09 17:51:03 INF] Opening the com port COM8 [ 2023-08-09 17:51:04 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 17:51:04 INF] Timeout, try again! [ 2023-08-09 17:51:04 INF] COM8 <<< Ping: 9 [ 2023-08-09 17:51:04 INF] Opening the com port COM8 [ 2023-08-09 17:51:05 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 17:51:05 INF] Timeout, try again! [ 2023-08-09 17:51:05 INF] COM8 Error while waiting device to be ready: ping timeout [ 2023-08-09 17:51:05 INF] COM8 <<< Ping: 9 [ 2023-08-09 17:51:05 INF] Opening the com port COM8 [ 2023-08-09 17:51:06 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 17:51:06 INF] Timeout, try again! [ 2023-08-09 17:51:06 INF] COM8 <<< Ping: 9 [ 2023-08-09 17:51:06 INF] Opening the com port COM8 [ 2023-08-09 17:51:07 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 17:51:07 INF] Timeout, try again! [ 2023-08-09 17:51:07 INF] COM8 <<< Ping: 9 [ 2023-08-09 17:51:07 INF] Opening the com port COM8 [ 2023-08-09 17:51:07 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 17:51:07 INF] Timeout, try again! [ 2023-08-09 17:51:07 INF] COM8 Error while waiting device to be ready: ping timeout [ 2023-08-09 17:51:07 INF] Device at COM8 incompatible with protocol bg.zk.zfp: invalid device info returned. [ 2023-08-09 17:51:07 INF] Probing (9/9)bg.zk.v2.zfp.com://COM8... [ 2023-08-09 17:51:07 INF] Device at COM8 incompatible with protocol bg.zk.v2.zfp: invalid device info returned. [ 2023-08-09 17:51:08 INF] Detecting done. Found 0 available printer(s). [ 2023-08-09 17:51:10 INF] Idle timer elapsed for the com port COM8 [ 2023-08-09 17:51:11 INF] Closing the com port COM8
Pass to operator is 1
Is this Bulgarian device and protocol?
By default password for operator 1 is "0000"
bg.dt.x.isl - "operator" : "1", "operatorPassword": "0000"
https://github.com/erpnet/ErpNet.FP#default-passwords-we-use-in-the-library
Is this Bulgarian device and protocol?
By default password for operator 1 is "0000"
bg.dt.x.isl - "operator" : "1", "operatorPassword": "0000"
https://github.com/erpnet/ErpNet.FP#default-passwords-we-use-in-the-library
Its moldavian device from tina.md
I changed pass to 0000 - and no effect
[ 2023-08-09 18:22:45 INF] Starting the service, version 1.1.0.721... [ 2023-08-09 18:22:45 INF] Autodetecting local printers... [ 2023-08-09 18:22:45 INF] Probing (1/9)bg.dt.x.isl.com://COM8... [ 2023-08-09 18:22:46 INF] COM8 <<< 01-30-30-32-3B-21-30-30-35-3A-31-05-30-31-3F-33-03 [ 2023-08-09 18:22:46 INF] Opening the com port COM8 [ 2023-08-09 18:22:46 INF] Keep Alive Background Service is started. [ 2023-08-09 18:22:46 INF] COM8 >>> 16-01-30-30-36-3A-21-30-30-35-3A-44-50-2D-31-35-30-4D-58-2C-36-30-39-34-32-38-20-32-30-4A-75-6C-32-33-20-31-33-35-33-2C-39-34-36-30-2C-30-30-30-30-30-30-30-30-2C-20-20-20-20-30-32-35-30-30-30-30-32-04-80-80-80-80-84-82-80-80-05-31-31-31-32-03 [ 2023-08-09 18:22:46 INF] Device at COM8 incompatible with protocol bg.dt.x.isl: invalid device info returned. [ 2023-08-09 18:22:46 INF] Probing (2/9)bg.dt.c.isl.com://COM8... [ 2023-08-09 18:22:46 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 18:22:46 INF] Com port COM8 allready opened! [ 2023-08-09 18:22:46 INF] COM8 >>> 16 [ 2023-08-09 18:22:46 INF] COM8 >>> 15 [ 2023-08-09 18:22:46 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 18:22:46 INF] Com port COM8 allready opened! [ 2023-08-09 18:22:46 INF] COM8 >>> 16 [ 2023-08-09 18:22:46 INF] COM8 >>> 15 [ 2023-08-09 18:22:46 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 18:22:46 INF] Com port COM8 allready opened! [ 2023-08-09 18:22:46 INF] COM8 >>> 16 [ 2023-08-09 18:22:46 INF] COM8 >>> 15 [ 2023-08-09 18:22:46 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 18:22:46 INF] Com port COM8 allready opened! [ 2023-08-09 18:22:46 INF] COM8 >>> 16 [ 2023-08-09 18:22:46 INF] COM8 >>> 15 [ 2023-08-09 18:22:46 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 18:22:46 INF] Com port COM8 allready opened! [ 2023-08-09 18:22:46 INF] COM8 >>> 16 [ 2023-08-09 18:22:46 INF] COM8 >>> 15 [ 2023-08-09 18:22:46 INF] COM8 <<< 01-25-21-5A-31-05-30-30-3D-36-03 [ 2023-08-09 18:22:46 INF] Com port COM8 allready opened! [ 2023-08-09 18:22:46 INF] COM8 >>> 16 [ 2023-08-09 18:22:46 INF] COM8 >>> 15 [ 2023-08-09 18:22:46 INF] Device at COM8 incompatible with protocol bg.dt.c.isl: invalid device info returned. [ 2023-08-09 18:22:46 INF] Probing (3/9)bg.dt.p.isl.com://COM8... [ 2023-08-09 18:22:46 INF] Device at COM8 incompatible with protocol bg.dt.p.isl: invalid device info returned. [ 2023-08-09 18:22:46 INF] Probing (4/9)bg.ed.isl.com://COM8... [ 2023-08-09 18:22:46 INF] Device at COM8 incompatible with protocol bg.ed.isl: invalid device info returned. [ 2023-08-09 18:22:46 INF] Probing (5/9)bg.dy.isl.com://COM8... [ 2023-08-09 18:22:46 INF] Device at COM8 incompatible with protocol bg.dy.isl: invalid device info returned. [ 2023-08-09 18:22:46 INF] Probing (6/9)bg.in.isl.com://COM8... [ 2023-08-09 18:22:46 INF] Device at COM8 incompatible with protocol bg.in.isl: invalid device info returned. [ 2023-08-09 18:22:46 INF] Probing (7/9)bg.is.icp.com://COM8... [ 2023-08-09 18:22:46 INF] COM8 <<< 02-30-30-30-30-30-30-30-3C-38-3E-03 [ 2023-08-09 18:22:46 INF] Com port COM8 allready opened! [ 2023-08-09 18:22:47 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 18:22:47 INF] COM8 Cannot read from channel: Timeout occured while reading from com port 'COM8' [ 2023-08-09 18:22:47 INF] Device at COM8 incompatible with protocol bg.is.icp: invalid device info returned. [ 2023-08-09 18:22:47 INF] Probing (8/9)bg.zk.zfp.com://COM8... [ 2023-08-09 18:22:47 INF] COM8 <<< Ping: 9 [ 2023-08-09 18:22:47 INF] Opening the com port COM8 [ 2023-08-09 18:22:48 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 18:22:48 INF] Timeout, try again! [ 2023-08-09 18:22:48 INF] COM8 <<< Ping: 9 [ 2023-08-09 18:22:48 INF] Opening the com port COM8 [ 2023-08-09 18:22:49 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 18:22:49 INF] Timeout, try again! [ 2023-08-09 18:22:49 INF] COM8 <<< Ping: 9 [ 2023-08-09 18:22:49 INF] Opening the com port COM8 [ 2023-08-09 18:22:50 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 18:22:50 INF] Timeout, try again! [ 2023-08-09 18:22:50 INF] COM8 Error while waiting device to be ready: ping timeout [ 2023-08-09 18:22:50 INF] COM8 <<< Ping: 9 [ 2023-08-09 18:22:50 INF] Opening the com port COM8 [ 2023-08-09 18:22:51 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 18:22:51 INF] Timeout, try again! [ 2023-08-09 18:22:51 INF] COM8 <<< Ping: 9 [ 2023-08-09 18:22:51 INF] Opening the com port COM8 [ 2023-08-09 18:22:51 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 18:22:51 INF] Timeout, try again! [ 2023-08-09 18:22:51 INF] COM8 <<< Ping: 9 [ 2023-08-09 18:22:51 INF] Opening the com port COM8 [ 2023-08-09 18:22:52 ERR] Timeout occured while reading from com port 'COM8' [ 2023-08-09 18:22:52 INF] Timeout, try again! [ 2023-08-09 18:22:52 INF] COM8 Error while waiting device to be ready: ping timeout [ 2023-08-09 18:22:52 INF] Device at COM8 incompatible with protocol bg.zk.zfp: invalid device info returned. [ 2023-08-09 18:22:52 INF] Probing (9/9)bg.zk.v2.zfp.com://COM8... [ 2023-08-09 18:22:52 INF] Device at COM8 incompatible with protocol bg.zk.v2.zfp: invalid device info returned. [ 2023-08-09 18:22:53 INF] Detecting done. Found 0 available printer(s). [ 2023-08-09 18:22:55 INF] Idle timer elapsed for the com port COM8 [ 2023-08-09 18:22:55 INF] Closing the com port COM8
Hello, Answer of ID request for your fiscal device is decoded as: DP-150MX,609428 20Jul23 1353,9460,00000000, 02500002 and there is missing part from required answer format, which is like: FP-700X,2.00 13May20 1042,6331,00000000,DT52XXXX,025XXXXX
Missing part (like "DT52XXXX,") is Fiscal Device Number and is essential and required. This means that your device can not be supported by this software.
What about support of datecs dp150 MX?