Closed whentotrade closed 2 months ago
try to update release by release, to find out, which release causes the problem.
sudo apt install evcc=x.xxx.x # Versionsnummer
There is absolutly nothing about OCPP in your config.
Please try the latest nightly build (Master).
@premultiply: not in the evcc config, but the keba box had a connection to the keba portal via OCPP, so tried to disable the opcc in the keba box (not evcc) and tested with ocpp enabled and disabled on the keba box - but this did not change anything and the problem was there regardless if I disabled or enabled the keba ocpp backend (as saied not in EVCC but I was thinking that the OCPP config in Keba could have caused problems with the latest updates, that was the reason I did almost a lot of trial and error to find a root-cause)
@VolkerK62 : I could do that, but then it required another 1-2h of debug and trial and error. I was thinking there should be some kind of documentation about what has changed in the communication between charger, evcc and car fomr 127.2 to 129? For me it is clear something must have changed, as everything worked over a long period. And nothing touched here. That would help me instead of requiring to debug every release and read the logs. I am a little tiered of fiddling around with 129 now for hours and gave up with rolling back. Hard if breaking changes seem to be introduced without documentation or at least explanation what has changed. Need to find a free slot of time to walk through releases step by step to find the one where it failed. Will report back. At least a good proposal. Thx
@premultiply : What is the sudo command to install the latest nighlty build? I understand the command to pick a version, but not how to install the latest nighly build. Thx
see the installation guide. https://docs.evcc.io/en/docs/installation/linux You must add the unstable (nightly) repository.
just for info:
an other way is, to visit cloudsmith https://cloudsmith.io/~evcc/packages/
there you can pick up every version number and use it with the above mentioned install command
latest nightly = 0.129.0+1723775018
Teste doch mal Keba Modbus... (UDP wird ja offiziel nicht mehr von evcc gepflegt). https://docs.evcc.io/docs/devices/chargers#keba-kecontact-p20-p30-cx-series
wichtig: die identifiers sind dann nur die ersten acht stellen, nicht die kompletten 16 Stellen der RFID Karte. ocpp brauchst du doch eigentlich nicht, du verwendest wahrscheinlich das Keba Portal!? Da trägst du ja auch die RFID-Karten ein, oder? Wenn du die Karten direkt in der Keba einträgst, dann stell auf Autorisierung "first local".
chargers:
- type: template
template: keba-modbus
host: 192.168.0.69
name: wallbox1
modbus: tcpip
id: 255
port: 502
welcomecharge: true
vehicles:
- name: AudiEtron
type: template
template: audi
title: ****
user: ****
password: ****
vin: ****
capacity: 95 # Akku-Kapa in kWh # Optional
phases: 3
identifiers:
- 686f6d65
/ Unfortunately your report is missing a detailed log file. Without log, we don‘t have the information for diagnosing the issue described. See https://docs.evcc.io/docs/faq#wie-kann-ich-ein-logfile-zur-fehleranalyse-erstellen.
This issue persists and I have done a complete test and you can see the full logs beldow. As stated already in the initial issue request:
[lp-1 ] WARN 2024/08/17 07:22:05 charger out of sync: expected enabled, got disabled [lp-1 ] DEBUG 2024/08/17 07:22:05 charger disable
You can see in the full log that after connecting the car, switching to minpv, it is still stuck in the UI with the label "Ready. Waiting for vehicle..." and is stuck there forever.
I mentioned these issues already in the initial request. Here is the full log, it is not completed.
@TobiasHuber1980 , thanks for your suggestion! I did this, but the problem is still the same.
The Keba box itself still reports the state "idle" / "warten"
[site ] DEBUG 2024/08/17 07:20:04 ---- [lp-1 ] DEBUG 2024/08/17 07:20:05 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:20:05 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:20:05 pv power: 342W [site ] DEBUG 2024/08/17 07:20:05 battery soc: 0% [site ] DEBUG 2024/08/17 07:20:05 battery power: 0W [site ] DEBUG 2024/08/17 07:20:05 grid meter: -0W [site ] DEBUG 2024/08/17 07:20:05 site power: 100W [lp-1 ] DEBUG 2024/08/17 07:20:05 !! session: chargeRater.chargedEnergy=1.0 - chargedAtStartup=0.0 [lp-1 ] DEBUG 2024/08/17 07:20:05 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:20:05 charger status: A [lp-1 ] INFO 2024/08/17 07:20:05 car disconnected [lp-1 ] DEBUG 2024/08/17 07:20:05 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] INFO 2024/08/17 07:20:05 vehicle updated: HH-VT-ETRON -> unknown [lp-1 ] DEBUG 2024/08/17 07:20:05 !! active phases: 1p = min(0p measured 0p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:20:05 set session soc limit: 0 [lp-1 ] DEBUG 2024/08/17 07:20:05 set session energy limit: 0 [site ] DEBUG 2024/08/17 07:20:14 ---- [lp-1 ] DEBUG 2024/08/17 07:20:14 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:20:14 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:20:14 pv power: 322W [site ] DEBUG 2024/08/17 07:20:15 battery soc: 0% [site ] DEBUG 2024/08/17 07:20:15 battery power: 0W [site ] DEBUG 2024/08/17 07:20:15 grid meter: 5W [site ] DEBUG 2024/08/17 07:20:15 site power: 105W [lp-1 ] DEBUG 2024/08/17 07:20:15 !! session: chargeRater.chargedEnergy=1.0 - chargedAtStartup=0.0 [lp-1 ] DEBUG 2024/08/17 07:20:15 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:20:15 charger status: A [site ] DEBUG 2024/08/17 07:20:24 ---- [lp-1 ] DEBUG 2024/08/17 07:20:24 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:20:24 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:20:24 pv power: 310W [site ] DEBUG 2024/08/17 07:20:25 battery soc: 0% [site ] DEBUG 2024/08/17 07:20:25 battery power: 0W [site ] DEBUG 2024/08/17 07:20:25 grid meter: 13W [site ] DEBUG 2024/08/17 07:20:25 site power: 113W [lp-1 ] DEBUG 2024/08/17 07:20:25 !! session: chargeRater.chargedEnergy=1.0 - chargedAtStartup=0.0 [lp-1 ] DEBUG 2024/08/17 07:20:25 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:20:25 charger status: A [site ] DEBUG 2024/08/17 07:20:34 ---- [lp-1 ] DEBUG 2024/08/17 07:20:34 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:20:34 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:20:34 pv power: 310W [site ] DEBUG 2024/08/17 07:20:35 battery soc: 0% [site ] DEBUG 2024/08/17 07:20:35 battery power: 0W [site ] DEBUG 2024/08/17 07:20:35 grid meter: 14W [site ] DEBUG 2024/08/17 07:20:35 site power: 114W [lp-1 ] DEBUG 2024/08/17 07:20:35 !! session: chargeRater.chargedEnergy=1.0 - chargedAtStartup=0.0 [lp-1 ] DEBUG 2024/08/17 07:20:35 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:20:35 charger status: A [site ] DEBUG 2024/08/17 07:20:44 ---- [lp-1 ] DEBUG 2024/08/17 07:20:44 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:20:44 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:20:44 pv power: 298W [site ] DEBUG 2024/08/17 07:20:45 battery soc: 0% [site ] DEBUG 2024/08/17 07:20:45 battery power: 0W [site ] DEBUG 2024/08/17 07:20:45 grid meter: 18W [site ] DEBUG 2024/08/17 07:20:45 site power: 118W [lp-1 ] DEBUG 2024/08/17 07:20:45 !! session: chargeRater.chargedEnergy=1.0 - chargedAtStartup=0.0 [lp-1 ] DEBUG 2024/08/17 07:20:45 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:20:45 charger status: A [site ] DEBUG 2024/08/17 07:20:54 ---- [lp-1 ] DEBUG 2024/08/17 07:20:54 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:20:54 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:20:54 pv power: 299W [site ] DEBUG 2024/08/17 07:20:55 battery soc: 0% [site ] DEBUG 2024/08/17 07:20:55 battery power: 0W [site ] DEBUG 2024/08/17 07:20:55 grid meter: 25W [site ] DEBUG 2024/08/17 07:20:55 site power: 125W [lp-1 ] DEBUG 2024/08/17 07:20:55 !! session: chargeRater.chargedEnergy=1.0 - chargedAtStartup=0.0 [lp-1 ] DEBUG 2024/08/17 07:20:55 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:20:55 charger status: B [lp-1 ] DEBUG 2024/08/17 07:20:55 charge start energy: 1.33e+04kWh [lp-1 ] INFO 2024/08/17 07:20:55 car connected [lp-1 ] DEBUG 2024/08/17 07:20:55 vehicle api refresh [lp-1 ] DEBUG 2024/08/17 07:20:55 pv timer elapse [lp-1 ] DEBUG 2024/08/17 07:20:55 pv timer inactive [lp-1 ] DEBUG 2024/08/17 07:20:55 charge total import: 13312.418kWh [main ] DEBUG 2024/08/17 07:20:56 vehicle status: B (HH-VT-ETRON) [lp-1 ] INFO 2024/08/17 07:20:56 vehicle updated: unknown -> HH-VT-ETRON [lp-1 ] DEBUG 2024/08/17 07:20:56 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:20:56 vehicle status: B [lp-1 ] DEBUG 2024/08/17 07:20:56 vehicle soc: 50% [lp-1 ] DEBUG 2024/08/17 07:20:56 vehicle soc limit: 100% [lp-1 ] DEBUG 2024/08/17 07:20:56 vehicle range: 170km [lp-1 ] DEBUG 2024/08/17 07:20:56 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:20:56 pv charge current: 0A = 0A + -0.543A (125W @ 1p) [lp-1 ] DEBUG 2024/08/17 07:20:56 pv enable timer reset [lp-1 ] DEBUG 2024/08/17 07:20:56 pv timer inactive [lp-1 ] DEBUG 2024/08/17 07:20:56 charger enable [lp-1 ] DEBUG 2024/08/17 07:20:56 wake-up timer: start [site ] DEBUG 2024/08/17 07:21:04 ---- [lp-1 ] DEBUG 2024/08/17 07:21:05 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:21:05 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:21:05 pv power: 293W [site ] DEBUG 2024/08/17 07:21:05 battery soc: 0% [site ] DEBUG 2024/08/17 07:21:05 battery power: 0W [site ] DEBUG 2024/08/17 07:21:05 grid meter: 31W [site ] DEBUG 2024/08/17 07:21:05 site power: 131W [lp-1 ] DEBUG 2024/08/17 07:21:05 vehicle odometer: 41652km [lp-1 ] DEBUG 2024/08/17 07:21:05 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:21:05 charger status: B [lp-1 ] DEBUG 2024/08/17 07:21:05 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:21:05 pv charge current: 0A = 0A + -0.57A (131W @ 1p) [lp-1 ] DEBUG 2024/08/17 07:21:05 projected site power 131W >= 0W disable threshold [lp-1 ] DEBUG 2024/08/17 07:21:05 pv disable timer start: 3m0s [lp-1 ] DEBUG 2024/08/17 07:21:05 pv disable in 3m0s [lp-1 ] DEBUG 2024/08/17 07:21:07 set charge mode: minpv [lp-1 ] DEBUG 2024/08/17 07:21:07 pv timer reset [lp-1 ] DEBUG 2024/08/17 07:21:07 pv timer inactive [site ] DEBUG 2024/08/17 07:21:07 ---- [lp-1 ] DEBUG 2024/08/17 07:21:07 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:21:07 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:21:07 pv power: 287W [site ] DEBUG 2024/08/17 07:21:07 battery soc: 0% [site ] DEBUG 2024/08/17 07:21:07 battery power: 0W [site ] DEBUG 2024/08/17 07:21:07 grid meter: 32W [site ] DEBUG 2024/08/17 07:21:07 site power: 132W [lp-1 ] DEBUG 2024/08/17 07:21:07 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:21:07 charger status: B [lp-1 ] DEBUG 2024/08/17 07:21:07 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:21:07 pv charge current: min 6A > 0A (132W @ 1p, battery: false) [site ] DEBUG 2024/08/17 07:21:14 ---- [lp-1 ] DEBUG 2024/08/17 07:21:14 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:21:14 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:21:14 pv power: 290W [site ] DEBUG 2024/08/17 07:21:15 battery soc: 0% [site ] DEBUG 2024/08/17 07:21:15 battery power: 0W [site ] DEBUG 2024/08/17 07:21:15 grid meter: 37W [site ] DEBUG 2024/08/17 07:21:15 site power: 137W [lp-1 ] DEBUG 2024/08/17 07:21:15 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:21:15 charger status: B [lp-1 ] DEBUG 2024/08/17 07:21:15 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:21:15 pv charge current: min 6A > 0A (137W @ 1p, battery: false) [site ] DEBUG 2024/08/17 07:21:24 ---- [lp-1 ] DEBUG 2024/08/17 07:21:24 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:21:24 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:21:24 pv power: 278W [site ] DEBUG 2024/08/17 07:21:25 battery soc: 0% [site ] DEBUG 2024/08/17 07:21:25 battery power: 0W [site ] DEBUG 2024/08/17 07:21:25 grid meter: 43W [site ] DEBUG 2024/08/17 07:21:25 site power: 143W [lp-1 ] DEBUG 2024/08/17 07:21:25 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:21:25 charger status: B [lp-1 ] DEBUG 2024/08/17 07:21:25 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:21:25 pv charge current: min 6A > 0A (143W @ 1p, battery: false) [site ] DEBUG 2024/08/17 07:21:34 ---- [lp-1 ] DEBUG 2024/08/17 07:21:34 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:21:34 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:21:34 pv power: 267W [site ] DEBUG 2024/08/17 07:21:35 battery soc: 0% [site ] DEBUG 2024/08/17 07:21:35 battery power: 0W [site ] DEBUG 2024/08/17 07:21:35 grid meter: 53W [site ] DEBUG 2024/08/17 07:21:35 site power: 153W [lp-1 ] DEBUG 2024/08/17 07:21:35 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:21:35 charger status: B [lp-1 ] DEBUG 2024/08/17 07:21:35 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:21:35 pv charge current: min 6A > 0A (153W @ 1p, battery: false) [site ] DEBUG 2024/08/17 07:21:44 ---- [lp-1 ] DEBUG 2024/08/17 07:21:44 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:21:44 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:21:44 pv power: 213W [site ] DEBUG 2024/08/17 07:21:45 battery soc: 0% [site ] DEBUG 2024/08/17 07:21:45 battery power: 0W [site ] DEBUG 2024/08/17 07:21:45 grid meter: 60W [site ] DEBUG 2024/08/17 07:21:45 site power: 160W [lp-1 ] DEBUG 2024/08/17 07:21:45 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:21:45 charger status: B [lp-1 ] DEBUG 2024/08/17 07:21:45 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:21:45 pv charge current: min 6A > 0A (160W @ 1p, battery: false) [site ] DEBUG 2024/08/17 07:21:54 ---- [lp-1 ] DEBUG 2024/08/17 07:21:54 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:21:54 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:21:54 pv power: 209W [site ] DEBUG 2024/08/17 07:21:55 battery soc: 0% [site ] DEBUG 2024/08/17 07:21:55 battery power: 0W [site ] DEBUG 2024/08/17 07:21:55 grid meter: 70W [site ] DEBUG 2024/08/17 07:21:55 site power: 170W [lp-1 ] DEBUG 2024/08/17 07:21:55 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:21:55 charger status: B [lp-1 ] DEBUG 2024/08/17 07:21:55 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:21:55 pv charge current: min 6A > 0A (170W @ 1p, battery: false) [site ] DEBUG 2024/08/17 07:22:04 ---- [lp-1 ] DEBUG 2024/08/17 07:22:05 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:22:05 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:22:05 pv power: 212W [site ] DEBUG 2024/08/17 07:22:05 battery soc: 0% [site ] DEBUG 2024/08/17 07:22:05 battery power: 0W [site ] DEBUG 2024/08/17 07:22:05 grid meter: 70W [site ] DEBUG 2024/08/17 07:22:05 site power: 170W [lp-1 ] DEBUG 2024/08/17 07:22:05 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:22:05 charger status: B [lp-1 ] WARN 2024/08/17 07:22:05 charger out of sync: expected enabled, got disabled [lp-1 ] DEBUG 2024/08/17 07:22:05 charger disable [lp-1 ] DEBUG 2024/08/17 07:22:05 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:22:05 pv charge current: min 6A > 0A (170W @ 1p, battery: false) [lp-1 ] DEBUG 2024/08/17 07:22:05 charger enable [lp-1 ] DEBUG 2024/08/17 07:22:05 wake-up timer: start [site ] DEBUG 2024/08/17 07:22:14 ---- [lp-1 ] DEBUG 2024/08/17 07:22:14 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:22:14 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:22:14 pv power: 203W [site ] DEBUG 2024/08/17 07:22:15 battery soc: 0% [site ] DEBUG 2024/08/17 07:22:15 battery power: 0W [site ] DEBUG 2024/08/17 07:22:15 grid meter: 156W [site ] DEBUG 2024/08/17 07:22:15 site power: 256W [lp-1 ] DEBUG 2024/08/17 07:22:15 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:22:15 charger status: B [lp-1 ] DEBUG 2024/08/17 07:22:15 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:22:15 pv charge current: min 6A > 0A (256W @ 1p, battery: false) [site ] DEBUG 2024/08/17 07:22:24 ---- [lp-1 ] DEBUG 2024/08/17 07:22:24 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:22:24 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:22:24 pv power: 195W [site ] DEBUG 2024/08/17 07:22:25 battery soc: 0% [site ] DEBUG 2024/08/17 07:22:25 battery power: 0W [site ] DEBUG 2024/08/17 07:22:25 grid meter: 592W [site ] DEBUG 2024/08/17 07:22:25 site power: 692W [lp-1 ] DEBUG 2024/08/17 07:22:25 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:22:25 charger status: B [lp-1 ] DEBUG 2024/08/17 07:22:25 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:22:25 pv charge current: min 6A > 0A (692W @ 1p, battery: false) [site ] DEBUG 2024/08/17 07:22:34 ---- [lp-1 ] DEBUG 2024/08/17 07:22:34 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:22:34 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:22:34 pv power: 191W [site ] DEBUG 2024/08/17 07:22:35 battery soc: 0% [site ] DEBUG 2024/08/17 07:22:35 battery power: 0W [site ] DEBUG 2024/08/17 07:22:35 grid meter: 1467W [site ] DEBUG 2024/08/17 07:22:35 site power: 1567W [lp-1 ] DEBUG 2024/08/17 07:22:35 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:22:35 charger status: B [lp-1 ] DEBUG 2024/08/17 07:22:35 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:22:35 pv charge current: min 6A > 0A (1567W @ 1p, battery: false) [site ] DEBUG 2024/08/17 07:22:44 ---- [lp-1 ] DEBUG 2024/08/17 07:22:44 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:22:44 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:22:44 pv power: 170W [site ] DEBUG 2024/08/17 07:22:45 battery soc: 0% [site ] DEBUG 2024/08/17 07:22:45 battery power: 0W [site ] DEBUG 2024/08/17 07:22:45 grid meter: 1621W [site ] DEBUG 2024/08/17 07:22:45 site power: 1721W [lp-1 ] DEBUG 2024/08/17 07:22:45 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:22:45 charger status: B [lp-1 ] DEBUG 2024/08/17 07:22:45 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:22:45 pv charge current: min 6A > 0A (1721W @ 1p, battery: false) [lp-1 ] DEBUG 2024/08/17 07:22:45 wake-up vehicle, attempts left: 4 [site ] DEBUG 2024/08/17 07:22:54 ---- [lp-1 ] DEBUG 2024/08/17 07:22:54 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:22:54 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:22:54 pv power: 170W [site ] DEBUG 2024/08/17 07:22:55 battery soc: 0% [site ] DEBUG 2024/08/17 07:22:55 battery power: 0W [site ] DEBUG 2024/08/17 07:22:55 grid meter: 1883W [site ] DEBUG 2024/08/17 07:22:55 site power: 1983W [lp-1 ] DEBUG 2024/08/17 07:22:55 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:22:55 charger status: B [lp-1 ] DEBUG 2024/08/17 07:22:55 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:22:55 pv charge current: min 6A > 0A (1983W @ 1p, battery: false) [site ] DEBUG 2024/08/17 07:23:04 ---- [lp-1 ] DEBUG 2024/08/17 07:23:05 charge power: 0W [lp-1 ] DEBUG 2024/08/17 07:23:05 charge currents: [0 0 0]A [site ] DEBUG 2024/08/17 07:23:05 pv power: 175W [site ] DEBUG 2024/08/17 07:23:05 battery soc: 0% [site ] DEBUG 2024/08/17 07:23:05 battery power: 0W [site ] DEBUG 2024/08/17 07:23:05 grid meter: 1162W [site ] DEBUG 2024/08/17 07:23:05 site power: 1262W [lp-1 ] DEBUG 2024/08/17 07:23:05 charge total import: 13312.418kWh [lp-1 ] DEBUG 2024/08/17 07:23:05 charger status: B [lp-1 ] WARN 2024/08/17 07:23:05 charger out of sync: expected enabled, got disabled [lp-1 ] DEBUG 2024/08/17 07:23:05 charger disable [lp-1 ] DEBUG 2024/08/17 07:23:05 !! active phases: 1p = min(0p measured 3p vehicle 1p physical 0p charger) [lp-1 ] DEBUG 2024/08/17 07:23:05 pv charge current: min 6A > 0A (1262W @ 1p, battery: false) [lp-1 ] DEBUG 2024/08/17 07:23:05 charger enable [lp-1 ] DEBUG 2024/08/17 07:23:05 wake-up timer: start [site ] DEBUG 2024/08/17 07:23:14 ----
@andig :Not sure why you closed it so swiftly now forcing me to reopen as new issue: #15441 #15441
Not sure why you closed it so swiftly
Geschlossen da unvollständig. Siehe Issuetemplate.
EVCC not charging since upgrade to 129.0 for KEBA and Audi templates, EVCC stuck in "waiting for vehicle to start"
I had the evcc and my keba running stable over a long period, until I upgraded from 127.2 to 129.0.
Got a lot of error messages in the log, like "out of sync: expected enabled, got disabled", or "recv timeout message", I have no clue what to read out of that as my config worked for months now very stable without a single issue, did not change anything. I browsed the docs and comments here but this get above my level to understand all these possible discussions on "autostart" "nostop", OCCP communication, or whatever you might have changed and causes now new issues, I really spend 2 hours now trying almost all settings on my keba box (enabled OCPP completly, disabled RFID, etc.) but dont get it to work. And it worked absoltly perfect before. So there must have been a change on your end?
I moved back to version 127.2 and everything is working back again. But that cant be the solution.
I have no clue what you changed that make it broke. The documentation does not give me any clue and I am not a technician which understand the technical discussion in the issues coming up since the past 2-3 weeks on similar issues.
Can you please help to describe the changes the introduced between 127.2 to 129 that make it broke now? Using standard loadpoint and keba/audi templates.
I am even a sponsor.
Thanks & Regards, Lars
Steps to reproduce
Connect car, start charging. Charging is not starting. Info in evcc is: Charging started. Waiting for vehicle...... and nothing is happening.
Configuration details
Log details
What type of operating system are you running?
Linux
Version
129.0