Aktuell funktioniert das laden des Akkus über Netz nicht mehr.
Plenticore 5.5 gen2 + KSME
byd 7.7 akku
Steps to reproduce
Änderung in UI auf folgenden Wert:
folgende Situationen können entstehen
Kein PV Strom:
nach 5 Minuten steht weiterhin (entladen)
wird PV Strom erzeugt zieht das Haus Strom vom Netz und der Akku wird rein über PV geladen
Configuration details
network:
# schema is the HTTP schema
# setting to `https` does not enable https, it only changes the way URLs are generated
schema: http
# host is the hostname or IP address
# if the host name contains a `.local` suffix, the name will be announced on MDNS
# docker: MDNS announcements don't work. host must be set to the docker host's name.
host: 192.168.178.128
# port is the listening port for UI and api
# evcc will listen on all available interfaces
port: 7070
interval: 30s # control cycle interval. Interval <30s can lead to unexpected behavior, see https://docs.evcc.io/docs/reference/configuration/interval
# database configuration for persisting charge sessions and settings
# database:
# type: sqlite
# dsn: <path-to-db-file>
# trial token, valid until 2024-02-08
sponsortoken: eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJleHAiOjE4MDIwMzQwMDAsImlhdCI6MTcwNzQyNjAwMCwiaXNzIjoiZXZjYy5pbyIsInN1YiI6IlByZXNsMTk4MyIsInNyYyI6ImdoIn0.JatburjSbPVMIZt2vVTeRiboZVX2En6ezGsklagJT_k
# telemetry enables aggregated statistics
#
# Telemetry allows collecting usage data (grid and green energy, charge power).
# Data is aggregated, no individual charging sessions are tracked. The collected,
# anonymous data can be retrieved using https://api.evcc.io.
#
# See https://github.com/evcc-io/evcc/pull/4343 or details.
#
# For time being, this is only available to sponsors, hence data is associated with
# the sponsor token's identity.
#
# telemetry: true
# log settings
log: info
levels:
site: debug
lp-1: debug
lp-2: debug
cache: error
db: error
# modbus proxy for allowing external programs to reuse the evcc modbus connection
# each entry will start a proxy instance at the given port speaking Modbus TCP and
# relaying to the given modbus downstream device (either TCP or RTU, RS485 or TCP)
modbusproxy:
# - port: 5200
# uri: solar-edge:502
# # rtu: true
# # readonly: true # use `deny` to raise modbus errors
# meter definitions
# name can be freely chosen and is used as reference when assigning meters to site and loadpoints
# for documentation see https://docs.evcc.io/docs/devices/meters
meters:
- name: my_pv
type: template
template: kostal-plenticore-gen2
usage: pv
# Modbus TCP
modbus: tcpip
id: 71
host: 192.168.178.88 # Hostname
port: 1502 # Port
- name: my_grid
type: template
template: kostal-ksem-inverter
usage: grid
# Modbus TCP
modbus: tcpip
id: 71
host: 192.168.178.88 # Hostname
port: 1502 # Port
- name: my_battery
type: template
template: kostal-plenticore-gen2
usage: battery
modbus: tcpip
id: 71
host: 192.168.178.88 # Hostname
port: 1502 # Port
# endianness: little # optional
# capacity: 7.7 # Akkukapazität in kWh (optional)
# minsoc: 10 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
# maxsoc: 95 # optional
# watchdog: 60s # optional
# - name: my_grid
# type: template
# template: kostal-ksem
# usage: grid
# Modbus TCP
# modbus: tcpip
# id: 71
# host: 192.168.178.120 # Hostname
# port: 502 # Port
# Modbus TCP
# modbus: tcpip
# id: 71
# host: 192.168.178.88 # Hostname
# port: 1502 # Port
# charger definitions
# name can be freely chosen and is used as reference when assigning charger to vehicle
# for documentation see https://docs.evcc.io/docs/devices/chargers
chargers:
- name: my_charger
type: template
template: go-e-v3
host: 192.168.178.25 # IP-Adresse oder Hostname
# vehicle definitions
# name can be freely chosen and is used as reference when assigning vehicle to loadpoint
# for documentation see https://docs.evcc.io/docs/devices/vehicles
vehicles:
- name: my_car
type: template
template: tesla-command
title: Tesla # Wird in der Benutzeroberfläche angezeigt (optional)
accessToken: eyJhbGciOiJSUzI1NiIsInR5cCI6IkpXVCIsImtpZCI6InE0dHg3Q1UyYzI2V1BiemwxZjZjanM3QnhzayJ9.eyJpc3MiOiJodHRwczovL2F1dGgudGVzR7Ff2JRoURnyyi-t4679vOY_3EmJyF7zvolzoQ6nAxnfZATY4RtHSsD9GOHlqUEXXHvSGYJ2uLV0NiJ6a1-1AlGFc-WYKl1BuWZgBTZZUy9oN2dkpr0fwS4rDBmGVKQNSONsrGBIqI63EfkRgQ3n4TZPFIdkMSePrT0vQ
refreshToken: EU_c395b4ac6f3de
capacity: 50 # Akkukapazität in kWh (optional)
# site describes the EVU connection, PV and home battery
site:
title: Home # display name for UI
meters:
grid: my_grid # grid meter
pv:
- my_pv # list of pv inverters/ meters
#battery:
# - my_battery # list of battery meters
residualPower: 0 # additional household usage margin
maxGridSupplyWhileBatteryCharging: 0 # ignore battery charging if AC consumption is above this value
# loadpoint describes the charger, charge meter and connected vehicle
loadpoints:
- title: Garage # display name for UI
charger: my_charger # charger
meter: my_grid # charge meter
mode: "off" # default charge mode to apply when vehicle is disconnected; use "off" to disable by default if charger is publicly available
# remaining settings are experts-only and best left at default values
priority: 0 # relative priority for concurrent charging in PV mode with multiple loadpoints (higher values have higher priority)
soc:
# polling defines usage of the vehicle APIs
# Modifying the default settings it NOT recommended. It MAY deplete your vehicle's battery
# or lead to vehicle manufacturer banning you from API use. USE AT YOUR OWN RISK.
poll:
# poll mode defines under which condition the vehicle API is called:
# charging: update vehicle ONLY when charging (this is the recommended default)
# connected: update vehicle when connected (not only charging), interval defines how often
# always: always update vehicle regardless of connection state, interval defines how often (only supported for single vehicle)
mode: charging
# poll interval defines how often the vehicle API may be polled if NOT charging
interval: 60m
estimate: true # set false to disable interpolating between api updates (not recommended)
enable: # pv mode enable behavior
delay: 1m # threshold must be exceeded for this long
threshold: 0 # grid power threshold (in Watts, negative=export). If zero, export must exceed minimum charge power to enable
disable: # pv mode disable behavior
delay: 3m # threshold must be exceeded for this long
threshold: 0 # maximum import power (W)
guardDuration: 5m # switch charger contactor not more often than this (default 5m)
# tariffs are the fixed or variable tariffs
tariffs:
currency: EUR # three letter ISO-4217 currency code (default EUR)
grid:
type: awattar
region: at # optional, choose at for Austria
charges: 0.0144 # optional, additional charges per kWh
tax: 0.2 # optional, additional tax (0.1 for 10%)
feedin:
# rate for feeding excess (pv) energy to the grid
type: fixed
price: 0.058 # EUR/kWh
# type: octopusenergy
# tariff: AGILE-FLEX-22-11-25 # Tariff code
# region: A # optional
co2:
# co2 tariff provides co2 intensity forecast and is for co2-optimized target charging if no variable grid tariff is specified
# type: grünstromindex # GrünStromIndex (Germany only)
# zip: <zip>
# type: electricitymaps # https://app.electricitymaps.com/map
# uri: <uri>
# token: <token> # needs to be a token with forecast (not in the free tier)
# zone: DE
# type: ngeso # National Grid Electricity System Operator data (United Kingdom only) https://carbonintensity.org.uk/
# provides national data if both region and postcode are omitted - do not supply both at the same time!
# region: 1 # optional, coarser than using a postcode - see https://api.carbonintensity.org.uk/ for full list
# postcode: SW1A1AA # optional
# mqtt message broker
mqtt:
broker: 192.168.178.128:1883
topic: evcc # root topic for publishing, set empty to disable
user: mqtt-user
password: Carola_19081981
# influx database
influx:
# url: http://localhost:8086
# database: evcc
# user:
# password:
# eebus credentials
eebus:
# uri: # :4712
# interfaces: # limit eebus to specific network interfaces
# - en0
# certificate: # local signed certificate, required, can be generated via `evcc eebus-cert`
# public: # public key
# private: # private key
# push messages
messaging:
events:
start: # charge start event
title: Charge started
msg: Started charging in "${mode}" mode
stop: # charge stop event
title: Charge finished
msg: Finished charging ${chargedEnergy:%.1fk}kWh in ${chargeDuration}.
connect: # vehicle connect event
title: Car connected
msg: "Car connected at ${pvPower:%.1fk}kW PV"
disconnect: # vehicle connected event
title: Car disconnected
msg: Car disconnected after ${connectedDuration}
soc: # vehicle soc update event
title: Soc updated
msg: Battery charged to ${vehicleSoc:%.0f}%
guest: # vehicle could not be identified
title: Unknown vehicle
msg: Unknown vehicle, guest connected?
services:
# - type: pushover
# app: # app id
# recipients:
# - # list of recipient ids
# - type: telegram
# token: # bot id
# chats:
# - # list of chat ids
# - type: email
# uri: smtp://<user>:<password>@<host>:<port>/?fromAddress=<from>&toAddresses=<to>
# - type: ntfy
# uri: https://<host>/<topics>
# priority: <priority>
# tags: <tags>
Describe the bug
Aktuell funktioniert das laden des Akkus über Netz nicht mehr.
Plenticore 5.5 gen2 + KSME byd 7.7 akku
Steps to reproduce
folgende Situationen können entstehen Kein PV Strom:
Configuration details
Log details
What type of operating system are you running?
Linux
Nightly build
Version
0.131.4