Seit gestern habe ich die nachfolgenden Werte zur Auswahl:
Steps to reproduce
Preisgrenze Netzladen für Batterie als auch Auto
Configuration details
network:
# schema is the HTTP schema
# setting to `https` does not enable https, it only changes the way URLs are generated
schema: http
# host is the hostname or IP address
# if the host name contains a `.local` suffix, the name will be announced on MDNS
# docker: MDNS announcements don't work. host must be set to the docker host's name.
host: evcc.local
# port is the listening port for UI and api
# evcc will listen on all available interfaces
port: 7070
interval: 30s # control cycle interval. Interval <30s can lead to unexpected behavior, see https://docs.evcc.io/docs/reference/configuration/interval
# database configuration for persisting charge sessions and settings
# database:
# type: sqlite
# dsn: <path-to-db-file>
# sponsor token enables optional features (request at https://sponsor.evcc.io)
sponsortoken: eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.eyJpc3MiOiJldmNjLmlvIiwic3ViIjoiQWFyb25HOTAiLCJleHAiOjE4MDI2MTAwMDAsImlhdCI6MTcwODAwMjAwMCwic3JjIjoiZ2gifQ._mvBVnztvdjbiQzRXbPdtvHIFr6gmgwTIxigSgVJ7UM
# telemetry enables aggregated statistics
#
# Telemetry allows collecting usage data (grid and green energy, charge power).
# Data is aggregated, no individual charging sessions are tracked. The collected,
# anonymous data can be retrieved using https://api.evcc.io.
#
# See https://github.com/evcc-io/evcc/pull/4343 or details.
#
# For time being, this is only available to sponsors, hence data is associated with
# the sponsor token's identity.
#
# telemetry: true
# log settings
log: info
levels:
site: debug
lp-1: debug
lp-2: debug
cache: error
db: error
# modbus proxy for allowing external programs to reuse the evcc modbus connection
# each entry will start a proxy instance at the given port speaking Modbus TCP and
# relaying to the given modbus downstream device (either TCP or RTU, RS485 or TCP)
modbusproxy:
# - port: 5200
# uri: solar-edge:502
# # rtu: true
# # readonly: true # use `deny` to raise modbus errors
# meter definitions
# name can be freely chosen and is used as reference when assigning meters to site and loadpoints
# for documentation see https://docs.evcc.io/docs/devices/meters
meters:
- type: template
template: huawei-dongle-powersensor
id: 1
host: 192.168.178.92
port: 502
usage: grid
modbus: tcpip
name: grid1
- type: template
template: huawei-dongle-powersensor
id: 1
host: 192.168.178.92
port: 502
usage: pv
modbus: tcpip
name: pv2
- type: template
template: huawei-dongle-powersensor
id: 1
host: 192.168.178.92
port: 502
usage: battery
modbus: tcpip
name: battery3
# charger definitions
# name can be freely chosen and is used as reference when assigning charger to vehicle
# for documentation see https://docs.evcc.io/docs/devices/chargers
chargers:
- type: template
template: abl
id: 1
host: 192.168.178.201
port: 502
modbus: rs485tcpip
name: wallbox5
# vehicle definitions
# name can be freely chosen and is used as reference when assigning vehicle to loadpoint
# for documentation see https://docs.evcc.io/docs/devices/vehicles
vehicles:
- type: template
template: tesla-command
title: Model Y
accessToken: eyJhbGciOiJSUzI1NiIsInR5cCI6IkpXVCIsImtpZCI6InE0dHg3Q1UyYzI2V1BiemwxZjZjanM3QnhzayJ9.eyJpc3MiOiJodHRwczovL2F1dGgudGVzbGEuY29tL29hdXRoMi92My9udHMiLCJhenAiOiIwOGZmODI3ZmEzMWItNGVhNi1iZWQxLTgxN2JlMGFiNDBjOCIsInN1YiI6IjM1MDEwN2M1LTdmMzMtNDliZi04MjQ2LWViNDU5ZDVkMTk5OCIsImF1ZCI6WyJodHRwczovL2ZsZWV0LWFwaS5wcmQubmEudm4uY2xvdWQudGVzbGEuY29tIiwiaHR0cHM6Ly9mbGVldC1hcGkucHJkLmV1LnZuLmNsb3VkLnRlc2xhLmNvbSIsImh0dHBzOi8vYXV0aC50ZXNsYS5jb20vb2F1dGgyL3YzL3VzZXJpbmZvIl0sInNjcCI6WyJvcGVuaWQiLCJvZmZsaW5lX2FjY2VzcyIsInVzZXJfZGF0YSIsInZlaGljbGVfZGV2aWNlX2RhdGEiLCJ2ZWhpY2xlX2NtZHMiLCJ2ZWhpY2xlX2NoYXJnaW5nX2NtZHMiXSwiYW1yIjpbInB3ZCIsIm1mYSIsIm90cCJdLCJleHAiOjE3MDgwMzkxOTMsImlhdCI6MTcwODAxMDM5Mywib3VfY29kZSI6IkVVIiwibG9jYWxlIjoiZGUtREUiLCJhdXRoX3RpbWUiOjE3MDgwMTAzOTJ9.FJqspQctfb9JEm4TI4vjQhpJ7N1RBzEPyISKHuXinGaBFfO1bDbIolQ_g19JBLMnRHMwd_vNPKt03e26vRQedqL5Nq4I1aKqFAhK74sic4oAr0Wrjp63JHCix3FWwupZeH6nJn74KoqkczNmgv7Y0Xz2HRWLFC-Z6RRevhabus1qxqqCqi54sOXx3ik6gkQPhrMTiFhgr6-5GsAkGoYqt4Dj4l5UbE5-Ir5GQ2dVNjZ7EISaE3xtdTOQRrNVxN2h-kYZSoA593GL6BCA4tcX7UOUbwphYuP5ZprQChFfZ19zEl7ivJb0-njd0ouNjaWjqHsk74rxN-pvkjTmU5fBug
refreshToken: EU_6d412563b68bbb6ad9f752bab587b516f2333097f07cb57cb8de81f30c208879
capacity: 82
name: ev4
mode: pv # enable PV-charging when vehicle is identified
# site describes the EVU connection, PV and home battery
site:
title: Zuhause
meters:
grid: grid1
pv:
- pv2
battery:
- battery3
# loadpoint describes the charger, charge meter and connected vehicle
loadpoints:
- title: Garage
charger: wallbox5
vehicle: ev4
mode: pv
phases: 3
mincurrent: 6
maxcurrent: 16
# tariffs are the fixed or variable tariffs
tariffs:
currency: EUR # three letter ISO-4217 currency code (default EUR)
grid:
# either static grid price (or price zones)
# type: fixed
# price: 0.2893 # EUR/kWh
# zones:
# - days: Mon-Fri
# hours: 2-5
# price: 0.2 # EUR/kWh
# - days: Sat,Sun
# price: 0.15 # EUR/kWh
# or variable tariffs
type: tibber
token: "AmgysyZ-4ju52qoNRbTcH_cHEdN6R27qRXXFggv3Zlg" # access token
# homeid: "cc83e83e-8cbf-4595-9bf7-c3cf192f7d9c" # optional if multiple homes associated to account
# type: awattar
# region: de # optional, choose at for Austria
# charges: # optional, additional charges per kWh
# tax: # optional, additional tax (0.1 for 10%)
# type: octopusenergy
# tariff: AGILE-FLEX-22-11-25 # Tariff code
# region: A # optional
# type: elering # Nordpool
# region: ee # or lt, lv, fi
# charges: # optional, additional charges per kWh
# tax: # optional, additional tax (0.1 for 10%)
# type: energinet # Energinet using the price in DKK
# region: dk1 # or dk2
# charges: # optional, additional charges per kWh
# tax: # optional, additional tax (0.1 for 10%)
# type: entsoe # Entso-E european market data
# domain: BZN|DE-LU # https://transparency.entsoe.eu/content/static_content/Static%20content/web%20api/Guide.html#_areas
# securitytoken: # api token
# charges: # optional, additional charges per kWh
# tax: # optional, additional tax (0.1 for 10%)
# type: custom # price from a plugin source; see https://docs.evcc.io/docs/reference/plugins
# price:
# source: http
# uri: https://example.org/price.json
# jq: .price.current
feedin:
# rate for feeding excess (pv) energy to the grid
type: fixed
price: 0.08 # EUR/kWh
# type: octopusenergy
# tariff: AGILE-FLEX-22-11-25 # Tariff code
# region: A # optional
co2:
# co2 tariff provides co2 intensity forecast and is for co2-optimized target charging if no variable grid tariff is specified
# type: grünstromindex # GrünStromIndex (Germany only)
# zip: <zip>
# type: electricitymaps # https://app.electricitymaps.com/map
# uri: <uri>
# token: <token> # needs to be a token with forecast (not in the free tier)
# zone: DE
# type: ngeso # National Grid Electricity System Operator data (United Kingdom only) https://carbonintensity.org.uk/
# provides national data if both region and postcode are omitted - do not supply both at the same time!
# region: 1 # optional, coarser than using a postcode - see https://api.carbonintensity.org.uk/ for full list
# postcode: SW1A1AA # optional
# mqtt message broker
mqtt:
# broker: localhost:1883
# topic: evcc # root topic for publishing, set empty to disable
# user:
# password:
# influx database
influx:
# url: http://localhost:8086
# database: evcc
# user:
# password:
# eebus credentials
eebus:
# uri: # :4712
# interfaces: # limit eebus to specific network interfaces
# - en0
# certificate: # local signed certificate, required, can be generated via `evcc eebus-cert`
# public: # public key
# private: # private key
# push messages
messaging:
events:
start: # charge start event
title: Charge started
msg: Started charging in "${mode}" mode
stop: # charge stop event
title: Charge finished
msg: Finished charging ${chargedEnergy:%.1fk}kWh in ${chargeDuration}.
connect: # vehicle connect event
title: Car connected
msg: "Car connected at ${pvPower:%.1fk}kW PV"
disconnect: # vehicle connected event
title: Car disconnected
msg: Car disconnected after ${connectedDuration}
soc: # vehicle soc update event
title: Soc updated
msg: Battery charged to ${vehicleSoc:%.0f}%
guest: # vehicle could not be identified
title: Unknown vehicle
msg: Unknown vehicle, guest connected?
services:
# - type: pushover
# app: # app id
# recipients:
# - # list of recipient ids
# - type: telegram
# token: # bot id
# chats:
# - # list of chat ids
# - type: email
# uri: smtp://<user>:<password>@<host>:<port>/?fromAddress=<from>&toAddresses=<to>
# - type: ntfy
# uri: https://<host>/<topics>
# priority: <priority>
# tags: <tags>
Log details
n/a
What type of operating system are you running?
Docker container
Nightly build
[X] I have verified that the issue is reproducible with the latest nightly build
Describe the bug
Seit gestern habe ich die nachfolgenden Werte zur Auswahl:
Steps to reproduce
Preisgrenze Netzladen für Batterie als auch Auto
Configuration details
Log details
What type of operating system are you running?
Docker container
Nightly build
Version
No response