Hi Fabian,

thanks a lot for the script. On my Raspi with Venus OS it's working fine.

My cousin has a Gerbo connected to a fritzbox. in this case the Gerbo has an IP V4 and an IP V6 Address!

From a SSH Terminal on the Gerbo the Shelly with the IP v4 address is not reachable by ping (also not with your script)

The shelly seems not to able to deal with a IP v6

Do you know if I can disable IP v6 on the Gerbo? Or any other idea?

Thx Michael

fabian-lauer commented 1 year ago

Hi @qwert4712 ,

sorry can't help here as I don't use IPv6 in my private network at all - maybe a tip (not sure if working) is to setup IP manually in web-interface like here: image

I also disabled WIFI at all, as connected via Ethernet.

For more assistance I would always recommend the Victron community: https://community.victronenergy.com/index.html

Fabian

qwert4712 commented 1 year ago

Thank you Fabian.

I already tried this.

in the remote console the V6 Address is not shown, only in the "Geräteliste" in the VRM Portal.

BR

qwert4712 commented 1 year ago

FYI the problem was not IP V6

There is a option ""Aktive WLAN-Geräte dürfen untereinander kommunizieren" on the Fritzbox. This was enabled on the Repeater but disabled on the Main Fritzbox.

When setting up the script the Gerbo seems to be conneted to the Repeater - because it work for about 6h. Then the connection failed. The Gerbo was then connected always to the Main Fritzbox and a ping of the Shelly failed.