Group Bind doesn't work #26

Closed pipiche38 closed 3 years ago

pipiche38 commented 3 years ago

If you use the Bind API ( 0x0030 ) where you can sepecify a Source IEEE and a GroupId with address mode 0x01, it looks like the group bind is not issue.

Not a single trace on the sniffer

pipiche38 commented 3 years ago

Data: {'Command': '0030', 'payload': '90fd9ffffeea89e8010006010000'}

Here is with ZiGate V1 Screenshot 2021-11-01 at 12 54 22

Here is with ZiGate V2 where the GroupId seems to be not the one expected Screenshot 2021-11-01 at 12 48 20

Then it is important to note than on V1, even if the Bind seems to be correct, the end result is not

Add ZiGate to group 0x0000 and then bind a remote on Cluster 0x0006 with group 0x0000, the Zigate doesn't report anything to the plugin