Closed pipiche38 closed 1 year ago
You can find this infos here : https://github.com/fairecasoimeme/Zlinky_TIC#powerconfiguration-cluster-0x0001----from-v12
RO= READ only - RP= Reportable - RW = Read/Write
So 0x0001/0x0001 is not reportable , and is then requesting the host to poll the value, in addition , I do not see the Alarm Cluster is that something you plan to do ? As I don't understand the purpose of the ThreshodMin/Max without an alarm cluster. which then would be preventing the fact to poll such value
And from the Zigbee standard
The alarm settings in this table require the Alarms cluster to be implemented on the same device - see De-
pendencies```
It looks like v12 is bringing an additional cluster 0x0001 with 3 values reported. Could you please provide if those can be configure reported or not, as I didn't see them in the documentation