fairecasoimeme / Zlinky_TIC

Téléinformation Linky autoalimenté ZigBee 3.0
290 stars 21 forks source link

Z2M: Failed to configure - Error: ConfigureReporting #187

Open dmartinpro opened 1 year ago

dmartinpro commented 1 year ago

Hi,

I've noticed this error message in Z2M logs:

Zigbee2MQTT:error 2023-03-13 19:35:17: Failed to configure '0x00158d0005be99f5', attempt 1 (Error: ConfigureReporting 0x00158d0005be99f5/1 haElectricalMeasurement([{"attribute":"totalReactivePower","minimumReportInterval":60,"maximumReportInterval":900,"reportableChange":1}], {"sendWhen":"immediate","timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Timeout - 49642 - 1 - 11 - 2820 - 7 after 10000ms) I've tried to restart Z2M, same issue. ZLinky version is 0013, Z2M is up to date (1.30.1).

What does it mean and how to get rid of it?

raspbeguy commented 11 months ago

I have the same behaviour on one of my 2 zlinky. The other one is fine. Data are correctly reported but this error shows up every time I restart z2m.

razmoket89 commented 11 months ago

Same issue here.