Missing value GRID voltage and consumtion, delivered power ok #198

Open hbk001 opened 12 months ago

hbk001 commented 12 months ago

Bonjour,

Lot of static info seems ok, but only delivered power value makes sence

OTA 4000 - 13 latest Z2M

Any sugestions?

A bientot HB Bandol

{ "active_enerfy_out_d01": 0, "active_power": 0, "active_power_max": 0, "active_power_ph_b": 0, "active_register_tier_delivered": "TH..", "apparent_power": 1130, "available_power": 12, "average_rms_voltage_meas_period": 0, "current_date": "E230705151517", "current_index_tarif": 1, "current_price": "BASE", "current_summ_delivered": 34454, "current_summ_received": 0, "current_tarif": "BASE", "current_tier1_summ_delivered": 34454, "current_tier2_summ_delivered": 0, "current_tier3_summ_delivered": 0, "current_tier4_summ_delivered": 0, "current_tier5_summ_delivered": 0, "current_tier6_summ_delivered": 0, "drawn_v_a_max_n1": 4765, "injected_active_load_n": 0, "injected_active_load_n1": 3168, "injected_v_a": 1770, "injected_v_a_max_n": 0, "injected_v_a_max_n1": 4928, "linkquality": 94, "message1": "PAS DE MESSAGE", "message2": "", "meter_serial_number": "061861753465", "power_threshold": 12, "reactive_power": 0, "reactive_power_ph_b": 0, "reactive_power_ph_c": 0, "relais": 0, "rms_current": 5, "rms_current_max": 90, "rms_voltage": 0, "schedule_h_p_h_c": 0, "site_id": "25362952213216", "software_revision": 2, "status_register": "003A4301", "tomorrow_color": "", "total_reactive_power": -11746, "update": { "installed_version": 13, "latest_version": 13, "state": "idle" }, "update_available": false, "warn_d_p_s": 0 } Log: error 2023-07-05 15:05:28Failed to configure '0x00158d000638dbc2', attempt 1 (Error: ConfigureReporting 0x00158d000638dbc2/1 haElectricalMeasurement([{"attribute":"totalReactivePower","minimumReportInterval":60,"maximumReportInterval":900,"reportableChange":1}], {"sendWhen":"immediate","timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (Timeout - 14236 - 1 - 226 - 2820 - 7 after 10000ms) at Timeout._onTimeout (/opt/zigbee2mqtt/node_modules/zigbee-herdsman/src/utils/waitress.ts:64:35) at listOnTimeout (node:internal/timers:559:17) at processTimers (node:internal/timers:502:7)) debug 2023-07-05 15:05:42Received Zigbee message from '0x00158d000638dbc2', type 'readResponse', cluster 'liXeePrivate', data '{"currentTarif":" BASE\u0000 "}' from endpoint 1 with groupID 0 info 2023-07-05 15:05:42Configuring '0x00158d000638dbc2' info 2023-07-05 15:05:42MQTT publish: topic 'zigbee2mqtt/0x00158d000638dbc2', payload '{"active_enerfy_out_d01":0,"active_power":0,"active_power_max":0,"active_power_ph_b":0,"active_register_tier_delivered":"TH..","apparent_power":1130,"available_power":12,"average_rms_voltage_meas_period":0,"current_date":"E230705150413","current_index_tarif":1,"current_price":"BASE","current_summ_delivered":34454,"current_summ_received":0,"current_tarif":"BASE","current_tier1_summ_delivered":34454,"current_tier2_summ_delivered":0,"current_tier3_summ_delivered":0,"current_tier4_summ_delivered":0,"current_tier5_summ_delivered":0,"current_tier6_summ_delivered":0,"drawn_v_a_max_n1":4765,"injected_active_load_n":0,"injected_active_load_n1":3168,"injected_v_a":1660,"injected_v_a_max_n":0,"injected_v_a_max_n1":4928,"linkquality":94,"message1":"PAS DE MESSAGE","message2":"","meter_serial_number":"061861753465","power_threshold":12,"reactive_power":0,"reactive_power_ph_b":0,"reactive_power_ph_c":0,"relais":0,"rms_current":5,"rms_current_max":90,"rms_voltage":0,"schedule_h_p_h_c":0,"site_id":"25362952213216","software_revision":2,"status_register":"003A4301","tomorrow_color":"","total_reactive_power":-11746,"update":{"installed_version":13,"latest_version":13,"state":"idle"},"update_available":false,"warn_d_p_s":0}' debug 2023-07-05 15:05:42Received Zigbee message from '0x00158d000638dbc2', type 'readResponse', cluster 'liXeePrivate', data '{"currentPrice":" BASE\u0000 "}' from endpoint 1 with groupID 0 info 2023-07-05 15:05:42MQTT publish: topic 'zigbee2mqtt/0x00158d000638dbc2', payload '{"active_enerfy_out_d01":0,"active_power":0,"active_power_max":0,"active_power_ph_b":0,"active_register_tier_delivered":"TH..","apparent_power":1130,"available_power":12,"average_rms_voltage_meas_period":0,"current_date":"E230705150413","current_index_tarif":1,"current_price":"BASE","current_summ_delivered":34454,"current_summ_received":0,"current_tarif":"BASE","current_tier1_summ_delivered":34454,"current_tier2_summ_delivered":0,"current_tier3_summ_delivered":0,"current_tier4_summ_delivered":0,"current_tier5_summ_delivered":0,"current_tier6_summ_delivered":0,"drawn_v_a_max_n1":4765,"injected_active_load_n":0,"injected_active_load_n1":3168,"injected_v_a":1660,"injected_v_a_max_n":0,"injected_v_a_max_n1":4928,"linkquality":94,"message1":"PAS DE MESSAGE","message2":"","meter_serial_number":"061861753465","power_threshold":12,"reactive_power":0,"reactive_power_ph_b":0,"reactive_power_ph_c":0,"relais":0,"rms_current":5,"rms_current_max":90,"rms_voltage":0,"schedule_h_p_h_c":0,"site_id":"25362952213216","software_revision":2,"status_register":"003A4301","tomorrow_color":"","total_reactive_power":-11746,"update":{"installed_version":13,"latest_version":13,"state":"idle"},"update_available":false,"warn_d_p_s":0}'