Hello,
Since a few month, i have a constant issue with my lixee and Zigbee2MQTT using a conbee adapter
It was working fine during almast one year and now i have no more information.
When i try to delete the lixee and repair it, it works during a few hour then failed back again.
My Conbee is located at 1m of my linky.
Below my configuration and part os Z2M log showing error, if you have any idea or solution to definitively fix this one, i'm in
Zigbee2MQTT:info 2024-03-18 10:18:54: MQTT publish: topic 'zigbee2mqtt/0x00158d0005d2912e', payload '{"active_energy_out_d01":4058.047,"active_energy_out_d02":0,"active_energy_out_d03":0,"active_energy_out_d04":0,"active_power":286,"active_power_max":1080,"active_power_ph_b":180,"apparent_power":567,"average_rms_voltage_meas_period":232,"current_summ_delivered":4016.93,"current_summ_received":2138.704,"current_tarif":"Base","current_tier10_summ_delivered":0,"current_tier1_summ_delivered":4016.93,"current_tier2_summ_delivered":0,"current_tier3_summ_delivered":0,"current_tier4_summ_delivered":0,"current_tier5_summ_delivered":0,"current_tier6_summ_delivered":0,"current_tier7_summ_delivered":0,"current_tier8_summ_delivered":0,"current_tier9_summ_delivered":0,"injected_active_load_n":0,"injected_v_a_max_n":540,"linkquality":255,"reactive_power":2018,"reactive_power_ph_b":-24692,"reactive_power_ph_c":13756,"rms_current":2,"rms_voltage":233,"status_register":"003A0300","status_register_breakout":{"cache_borne_dist":"ferme","comm_euridis":"activee avec securite","contact_sec":"ferme","depassement_ref_pow":0,"etat_cpl":"nouveau_verrouille","horloge":"correcte","organe_coupure":"ferme","pointe_mobile":"AUCUN","preavis_pointe_mobile":"AUCUN","producteur":1,"sens_energie_active":"negative","surtension_phase":0,"sync_cpl":"non_synchronise","tarif_dist":"index_1","tarif_four":"index_1","tempo_demain":"UNDEF","tempo_jour":"UNDEF","type_tic":"standard"},"update":{"installed_version":13,"latest_version":13,"state":"idle"},"update_available":false}'
Zigbee2MQTT:info 2024-03-18 10:18:55: MQTT publish: topic 'zigbee2mqtt/0x00158d0005d2912e', payload '{"active_energy_out_d01":4058.047,"active_energy_out_d02":0,"active_energy_out_d03":0,"active_energy_out_d04":0,"active_power":286,"active_power_max":1080,"active_power_ph_b":180,"apparent_power":567,"average_rms_voltage_meas_period":232,"current_summ_delivered":4016.93,"current_summ_received":2138.704,"current_tarif":"Base","current_tier10_summ_delivered":0,"current_tier1_summ_delivered":4016.93,"current_tier2_summ_delivered":0,"current_tier3_summ_delivered":0,"current_tier4_summ_delivered":0,"current_tier5_summ_delivered":0,"current_tier6_summ_delivered":0,"current_tier7_summ_delivered":0,"current_tier8_summ_delivered":0,"current_tier9_summ_delivered":0,"injected_active_load_n":0,"injected_v_a_max_n":540,"linkquality":255,"reactive_power":2018,"reactive_power_ph_b":-24692,"reactive_power_ph_c":13756,"rms_current":2,"rms_voltage":233,"status_register":"003A0100","status_register_breakout":{"cache_borne_dist":"ferme","comm_euridis":"activee avec securite","contact_sec":"ferme","depassement_ref_pow":0,"etat_cpl":"nouveau_verrouille","horloge":"correcte","organe_coupure":"ferme","pointe_mobile":"AUCUN","preavis_pointe_mobile":"AUCUN","producteur":1,"sens_energie_active":"positive","surtension_phase":0,"sync_cpl":"non_synchronise","tarif_dist":"index_1","tarif_four":"index_1","tempo_demain":"UNDEF","tempo_jour":"UNDEF","type_tic":"standard"},"update":{"installed_version":13,"latest_version":13,"state":"idle"},"update_available":false}'
zlinky config: standard, single_phase, true, Base
Zigbee2MQTT:info 2024-03-18 10:18:57: Configuring '0x00158d0005d2912e'
Zigbee2MQTT:info 2024-03-18 10:18:57: MQTT publish: topic 'zigbee2mqtt/0x00158d0005d2912e', payload '{"active_energy_out_d01":4058.047,"active_energy_out_d02":0,"active_energy_out_d03":0,"active_energy_out_d04":0,"active_power":286,"active_power_max":1080,"active_power_ph_b":180,"apparent_power":567,"average_rms_voltage_meas_period":232,"current_summ_delivered":4016.93,"current_summ_received":2138.704,"current_tarif":"Base","current_tier10_summ_delivered":0,"current_tier1_summ_delivered":4016.93,"current_tier2_summ_delivered":0,"current_tier3_summ_delivered":0,"current_tier4_summ_delivered":0,"current_tier5_summ_delivered":0,"current_tier6_summ_delivered":0,"current_tier7_summ_delivered":0,"current_tier8_summ_delivered":0,"current_tier9_summ_delivered":0,"injected_active_load_n":0,"injected_v_a_max_n":540,"linkquality":255,"reactive_power":2018,"reactive_power_ph_b":-24692,"reactive_power_ph_c":13756,"rms_current":2,"rms_voltage":233,"status_register":"003A0100","status_register_breakout":{"cache_borne_dist":"ferme","comm_euridis":"activee avec securite","contact_sec":"ferme","depassement_ref_pow":0,"etat_cpl":"nouveau_verrouille","horloge":"correcte","organe_coupure":"ferme","pointe_mobile":"AUCUN","preavis_pointe_mobile":"AUCUN","producteur":1,"sens_energie_active":"positive","surtension_phase":0,"sync_cpl":"non_synchronise","tarif_dist":"index_1","tarif_four":"index_1","tempo_demain":"UNDEF","tempo_jour":"UNDEF","type_tic":"standard"},"update":{"installed_version":13,"latest_version":13,"state":"idle"},"update_available":false}'
Zigbee2MQTT:info 2024-03-18 10:19:08: MQTT publish: topic 'zigbee2mqtt/0x00158d0005d2912e', payload '{"active_energy_out_d01":4058.047,"active_energy_out_d02":0,"active_energy_out_d03":0,"active_energy_out_d04":0,"active_power":286,"active_power_max":1080,"active_power_ph_b":180,"apparent_power":567,"average_rms_voltage_meas_period":232,"current_summ_delivered":4016.93,"current_summ_received":2138.704,"current_tarif":"Base","current_tier10_summ_delivered":0,"current_tier1_summ_delivered":4016.93,"current_tier2_summ_delivered":0,"current_tier3_summ_delivered":0,"current_tier4_summ_delivered":0,"current_tier5_summ_delivered":0,"current_tier6_summ_delivered":0,"current_tier7_summ_delivered":0,"current_tier8_summ_delivered":0,"current_tier9_summ_delivered":0,"injected_active_load_n":0,"injected_v_a_max_n":540,"linkquality":255,"reactive_power":2018,"reactive_power_ph_b":-24692,"reactive_power_ph_c":13756,"rms_current":2,"rms_voltage":233,"status_register":"003A0300","status_register_breakout":{"cache_borne_dist":"ferme","comm_euridis":"activee avec securite","contact_sec":"ferme","depassement_ref_pow":0,"etat_cpl":"nouveau_verrouille","horloge":"correcte","organe_coupure":"ferme","pointe_mobile":"AUCUN","preavis_pointe_mobile":"AUCUN","producteur":1,"sens_energie_active":"negative","surtension_phase":0,"sync_cpl":"non_synchronise","tarif_dist":"index_1","tarif_four":"index_1","tempo_demain":"UNDEF","tempo_jour":"UNDEF","type_tic":"standard"},"update":{"installed_version":13,"latest_version":13,"state":"idle"},"update_available":false}'
Zigbee2MQTT:error 2024-03-18 10:19:08: Failed to configure '0x00158d0005d2912e', attempt 4 (Error: ConfigureReporting 0x00158d0005d2912e/1 haElectricalMeasurement([{"attribute":"totalReactivePower","minimumReportInterval":60,"maximumReportInterval":900,"reportableChange":1}], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (no response received (113))
at DeconzAdapter.sendZclFrameToEndpoint (/app/node_modules/zigbee-herdsman/src/adapter/deconz/adapter/deconzAdapter.ts:666:23)
at Request.send (/app/node_modules/zigbee-herdsman/src/controller/helpers/request.ts:79:20)
at Endpoint.configureReporting (/app/node_modules/zigbee-herdsman/src/controller/model/endpoint.ts:669:28)
at async Promise.allSettled (index 15)
at Object.configure (/app/node_modules/zigbee-herdsman-converters/src/devices/lixee.ts:1025:14)
at Configure.configure (/app/lib/extension/configure.ts:122:13)
at Configure.onMQTTMessage (/app/lib/extension/configure.ts:55:21)
at EventEmitter.wrappedCallback (/app/lib/eventBus.ts:174:17))
Zigbee2MQTT:info 2024-03-18 10:19:08: MQTT publish: topic 'zigbee2mqtt/bridge/response/device/configure', payload '{"data":{"id":"0x00158d0005d2912e"},"error":"Failed to configure (ConfigureReporting 0x00158d0005d2912e/1 haElectricalMeasurement([{\"attribute\":\"totalReactivePower\",\"minimumReportInterval\":60,\"maximumReportInterval\":900,\"reportableChange\":1}], {\"timeout\":10000,\"disableResponse\":false,\"disableRecovery\":false,\"disableDefaultResponse\":true,\"direction\":0,\"srcEndpoint\":null,\"reservedBits\":0,\"manufacturerCode\":null,\"transactionSequenceNumber\":null,\"writeUndiv\":false}) failed (no response received (113)))","status":"error","transaction":"w0hj3-1"}'
zlinky config: standard, single_phase, true, Base
Zigbee2MQTT:info 2024-03-18 10:19:25: MQTT publish: topic 'zigbee2mqtt/0x00158d0005d2912e', payload '{"active_energy_out_d01":4058.047,"active_energy_out_d02":0,"active_energy_out_d03":0,"active_energy_out_d04":0,"active_power":286,"active_power_max":1080,"active_power_ph_b":180,"apparent_power":567,"average_rms_voltage_meas_period":232,"current_summ_delivered":4016.93,"current_summ_received":2138.704,"current_tarif":"Base","current_tier10_summ_delivered":0,"current_tier1_summ_delivered":4016.93,"current_tier2_summ_delivered":0,"current_tier3_summ_delivered":0,"current_tier4_summ_delivered":0,"current_tier5_summ_delivered":0,"current_tier6_summ_delivered":0,"current_tier7_summ_delivered":0,"current_tier8_summ_delivered":0,"current_tier9_summ_delivered":0,"injected_active_load_n":0,"injected_v_a_max_n":540,"linkquality":255,"reactive_power":2018,"reactive_power_ph_b":-24692,"reactive_power_ph_c":13756,"rms_current":2,"rms_voltage":234,"status_register":"003A0300","status_register_breakout":{"cache_borne_dist":"ferme","comm_euridis":"activee avec securite","contact_sec":"ferme","depassement_ref_pow":0,"etat_cpl":"nouveau_verrouille","horloge":"correcte","organe_coupure":"ferme","pointe_mobile":"AUCUN","preavis_pointe_mobile":"AUCUN","producteur":1,"sens_energie_active":"negative","surtension_phase":0,"sync_cpl":"non_synchronise","tarif_dist":"index_1","tarif_four":"index_1","tempo_demain":"UNDEF","tempo_jour":"UNDEF","type_tic":"standard"},"update":{"installed_version":13,"latest_version":13,"state":"idle"},"update_available":false}'
zlinky config: standard, single_phase, true, Base
zlinky config: standard, single_phase, true, Base
Hello, Since a few month, i have a constant issue with my lixee and Zigbee2MQTT using a conbee adapter
It was working fine during almast one year and now i have no more information. When i try to delete the lixee and repair it, it works during a few hour then failed back again.
My Conbee is located at 1m of my linky.
Below my configuration and part os Z2M log showing error, if you have any idea or solution to definitively fix this one, i'm in