Closed RemDelaporteMathurin closed 6 months ago
The values of the TMAP7 don't make sense to me.
This is the original data (thanks @fuerstT) in units D/m2/s
This is the figure from TMAP4 V&V
Now this is the figure from TMAP7
The units are different. When multiplying the original data by the surface (20 mm diameter) I cannot reproduce the TMAP7 experimental curve (pink)....
I've rewritten this validation case and used the TMAP4 parametrisation and modified the notes.
The values of the TMAP7 don't make sense to me.
This is the original data (thanks @fuerstT) in units D/m2/s
This is the figure from TMAP4 V&V
Now this is the figure from TMAP7
The units are different. When multiplying the original data by the surface (20 mm diameter) I cannot reproduce the TMAP7 experimental curve (pink)....
I've rewritten this validation case and used the TMAP4 parametrisation and modified the notes.