drjfloyd commented 2 years ago

The .out file no longer writes the HRR or RHRR. Here is the .out from couch.fds using the current source:

   Time Step      50   December 28, 2021  12:00:43
   Step Size:    0.659E-01 s, Total Time:       4.15 s
   Pressure Iterations: 1
   Maximum Velocity Error:  0.12E-01 on Mesh 1 at (16,8,11)
   Maximum Pressure Error:  0.82E+00 on Mesh 1 at (15,8,15)
   ---------------------------------------------------------------
   Max CFL number:  0.80E+00 at (15,8,13)
   Max divergence:  0.48E+00 at (16,8,7)
   Min divergence: -0.11E+00 at (15,8,14)
   Max VN number:   0.36E+00 at (15,8,21)
   No. of Lagrangian Particles:  3

   Time Step      60   December 28, 2021  12:00:43
mcgratta commented 2 years ago

OK, this is trickier than I thought.