Closed gforney closed 7 years ago
I changed the syntax. It is now
ORIENTATION(1:3,N)
where N is the index of the orientation vector in cases where there are more than one
orientations for a given Lagrangian particle.
Original issue reported on code.google.com by mcgratta
on 2013-06-24 12:37:44
In example of 'surf_mass_vent_nonchar_spher_gas',
&DEVC XYZ = 0.0,0.0,0.0,IOR = 3,
QUANTITY = 'SURFACE DENSITY',
ID = 'Surface density'
STATISTICS = 'SURFACE INTEGRAL'
XB = -0.5,0.5,-0.5,0.5,0.0,0.0 /
XYZ has no meaning.
Original issue reported on code.google.com by springcb38
on 2013-06-25 11:59:35
Thanks. I removed the XYZ in these DEVC lines.
Original issue reported on code.google.com by mcgratta
on 2013-06-25 14:28:06
When running the example of 'cable_11_insulation_mcc',
I encountered the following error statement.
ERROR: DEVC QUANTITY NORMALIZED HEAT RELEASE RATE not found
Original issue reported on code.google.com by springcb38
on 2013-06-26 01:06:24
Sorry!
I found that quantity in the latest data.f90 file.
Original issue reported on code.google.com by springcb38
on 2013-06-26 02:22:43
in User's Guide
Table 17.14
&MISC
CONSTANT_SPECIFIC_HEAT | Real |
->
CONSTANT_SPECIFIC_HEAT | Logical |
Original issue reported on code.google.com by springcb38
on 2013-09-13 09:27:51
Thanks. I fixed it.
Original issue reported on code.google.com by mcgratta
on 2013-09-13 12:17:05
in User's Guide
Table 17.26
SPREAD_RATE | | | | 0.
->
SPREAD_RATE | | | | 0.05
Table 17.30
SPREAD_RATE | | | | 0.0
->
SPREAD_RATE | | | | 0.05
Original issue reported on code.google.com by springcb38
on 2013-09-24 00:46:10
Thanks, I corrected it.
Original issue reported on code.google.com by mcgratta
on 2013-09-24 13:38:53
In User's Guide (FDS Version 6.0.0, SVN: 17354) page 96
&HVAC TYPE='FAN', ID='constant volume', VOLUME_FLOW=10.0/
&HVAC TYPE='FAN', ID='quadratic', MAX_FLOW=10., MAX_PRESSURE=500./
&HVAC TYPE='FAN', ID='user fan curve', RAMP_ID='fan curve'/
Should read (?):
&HVAC TYPE_ID='FAN', ID='constant volume', VOLUME_FLOW=10.0/
&HVAC TYPE_ID='FAN', ID='quadratic', MAX_FLOW=10., MAX_PRESSURE=500./
&HVAC TYPE_ID='FAN', ID='user fan curve', RAMP_ID='fan curve'/
Original issue reported on code.google.com by stefan.ledin@hsl.gsi.gov.uk
on 2013-11-20 15:05:21
yes thanks.
Original issue reported on code.google.com by drjfloyd
on 2013-11-20 15:10:22
In User's Guide (FDS Version 6.0.0, SVN: 17354) page 96
&RAMP ID='fan curve',F=-1000,T= 17.32/
&RAMP ID='fan curve',F= -800,T= 16.12/
&RAMP ID='fan curve',F= -600,T= 14.83/
&RAMP ID='fan curve',F= -400,T= 13.42/
&RAMP ID='fan curve',F= -200,T= 11.83/
&RAMP ID='fan curve',F= 0,T= 10.00/
&RAMP ID='fan curve',F= 200,T= 7.75/
&RAMP ID='fan curve',F= 400,T= 4.47/
&RAMP ID='fan curve',F= 600,T= -4.47/
&RAMP ID='fan curve',F= 800,T= -7.75/
&RAMP ID='fan curve',F= 1000,T=-10.00/
Should read (?):
&RAMP ID = 'fan curve', F = 1000, T = -10.00 /
&RAMP ID = 'fan curve', F = 800, T = -7.75 /
&RAMP ID = 'fan curve', F = 600, T = -4.47 /
&RAMP ID = 'fan curve', F = 400, T = 4.47 /
&RAMP ID = 'fan curve', F = 200, T = 7.75 /
&RAMP ID = 'fan curve', F = 0, T = 10.00 /
&RAMP ID = 'fan curve', F = -200, T = 11.83 /
&RAMP ID = 'fan curve', F = -400, T = 13.42 /
&RAMP ID = 'fan curve', F = -600, T = 14.83 /
&RAMP ID = 'fan curve', F = -800, T = 16.12 /
&RAMP ID = 'fan curve', F = -1000, T = 17.32 /
-------------------
FDS expects T to be given in increasing order
Original issue reported on code.google.com by stefan.ledin@hsl.gsi.gov.uk
on 2013-11-20 15:11:25
yes, thanks. At some point in developing HVAC I flipped which was T and which was F
for the fan curve and I guess I just switched T and F in the manual without reordering.
Original issue reported on code.google.com by drjfloyd
on 2013-11-20 15:18:18
FDS source code, read.f90
line 5081 :
THICKESS -> THICKNESS
Original issue reported on code.google.com by springcb38
on 2014-03-11 11:31:39
thanks.
Original issue reported on code.google.com by drjfloyd
on 2014-03-11 12:20:53
FDS source code, read.f90
line 8878 :
N_TRACKED_SPECIES > 0._EB
->
N_TRACKED_SPECIES > 0
Original issue reported on code.google.com by springcb38
on 2014-03-12 11:38:58
Got it, thanks.
Original issue reported on code.google.com by mcgratta
on 2014-03-12 12:22:31
hvac.f90
509 line :
.... Airocil ...
->
.... Aircoil ...
Original issue reported on code.google.com by springcb38
on 2014-03-17 01:17:19
thanks
Original issue reported on code.google.com by drjfloyd
on 2014-03-17 14:53:39
p.134
&REAC ID='R2'
A = 1.5e9
->
A = 3.98e8
by Andersen et al.
right?
Original issue reported on code.google.com by springcb38
on 2014-04-01 11:13:27
(No text was entered with this change)
Original issue reported on code.google.com by mcgratta
on 2014-04-01 15:53:03
p. 27
&REAC FUEL = 'HEPTANE'
->
&REAC FUEL = 'N-HEPTANE'
(although it's a section just for input file structure....)
Original issue reported on code.google.com by springcb38
on 2014-04-02 00:47:00
I changed the fuel name. Better to be consistent and not cause confusion.
Original issue reported on code.google.com by drjfloyd
on 2014-04-02 01:48:29
@springcb38, you are correct that the A from the paper is 3.98e8, but the parameter
used in the example is modified from source. If you look at the NIST RSE and FSE examples,
1.5e9 is used in R2.
Original issue reported on code.google.com by CraigWeinschenk
on 2014-04-03 15:23:00
UG p. 244
MASS_EXTINCTION_COEFFICIENT = 0
->
MASS_EXTINCTION_COEFFICIENT = 8700
Original issue reported on code.google.com by springcb38
on 2014-07-09 09:09:15
hvac.f90 (19676)
366 EFFICIENCY =1.0_EB
373 EFFICIENCY =0.0_EB
?
In USER's GUIDE, EFFICIENCY = 1.0
Original issue reported on code.google.com by springcb38
on 2014-07-24 09:42:50
Thank you.
Original issue reported on code.google.com by drjfloyd
on 2014-07-24 11:57:02
In FDS+Evac User's Guide,
34page,
door widht -> door width
74page, 8.1 The MESH Namelist Group
NO_EVACUATION is set to .FALSE. -> NO_EVACUATION is set to .TRUE.
78page, 8.6 The HOLE Namelist Group
for all evacuation mesh obstacles, -> for all evacuation mesh holes,
Original issue reported on code.google.com by springcb38
on 2015-02-10 10:46:23
INITIAL_VALUE is not a keyword on &CTRL namelist.
FDS User Guide 187page,
15.5.3 Control Function: DEADBAND
INITIAL_VALUE
-> initial value
Original issue reported on code.google.com by springcb38
on 2015-04-21 05:29:01
User's Guide, 14.4.4
For the cylinder, the area is twice the radius times the length
=>
For the cylinder, the area is 2pi times the radius times the length
Original issue reported on code.google.com by springcb38
on 2015-04-27 04:44:35
I fixed the typo mentioned in #81.
Original issue reported on code.google.com by mcgratta
on 2015-04-27 13:47:18
Are there any comments in this issue that have not been addressed? If so, start a new
issue. There might be more than one person needed to respond.
Original issue reported on code.google.com by mcgratta
on 2015-04-27 13:52:00
If Project Member make comment, I just thought that all my comments above that had been
resolved.
I did not check whether typo was fixed or not.
Original issue reported on code.google.com by springcb38
on 2015-04-28 02:32:53
read.f90
subroutine READ_DEVC
:
DV%CTRL_ID = CTRL_ID
DV%DEVC_ID = DEVC_ID
DV%CTRL_ID = CTRL_ID
:
"DV%CTRL_ID = CTRL_ID" line is repeated.
Original issue reported on code.google.com by springcb38
on 2015-05-10 06:57:22
read.f90
subroutine READ_DEVC
:
DV%CTRL_ID = CTRL_ID
DV%DEVC_ID = DEVC_ID
DV%CTRL_ID = CTRL_ID
:
"DV%CTRL_ID = CTRL_ID" line is repeated.
I fixed this.
Original issue reported on code.google.com by mcgratta
on 2015-05-11 14:07:28
The procedure of the subroutine call in read.f90 is the same with below.
:
CALL READ_MESH(1) ; IF (STOP_STATUS==SETUP_STOP) RETURN
CALL READ_EVAC(1) ; IF (STOP_STATUS==SETUP_STOP) RETURN
CALL READ_MESH(2) ; IF (STOP_STATUS==SETUP_STOP) RETURN
CALL READ_TRAN ; IF (STOP_STATUS==SETUP_STOP) RETURN
CALL READ_TIME ; IF (STOP_STATUS==SETUP_STOP) RETURN
:
Then, following is described at subroutine READ_TIME.
IF (.NOT.SYNCHRONIZE) SYNC_TIME_STEP = .FALSE.
This means that .not.SYNCHRONIZE on &TIME forces all SYNCHRONIZE on &MESH to .FALSE.
However, in user guide,
"It is also possible to synchronize the time step in only a select set of meshes. To
do this, add SYNCHRONIZE=.TRUE. to the appropriate MESH lines and then add SYNCHRONIZE=.FALSE.
to the TIME line."
There is inconsistency between source code and user's guide.
Original issue reported on code.google.com by springcb38
on 2015-05-18 12:29:15
Thanks. We plan to remove the SYNCHRONIZATION option, which will fix this inconsistency.
Original issue reported on code.google.com by mcgratta
on 2015-05-28 20:55:00
default value of SURFACE_TENSION in U.G
7.28e4
->
7.28e-2
Original issue reported on code.google.com by springcb38
on 2015-05-29 11:47:49
Do you plan to remove the SYNCHRONIZATION option ?
So,
SYNCHRONIZE=.FALSE. is implicitly applied ?
Original issue reported on code.google.com by springcb38
on 2015-05-29 11:50:07
No, SYNCHRONIZE=.TRUE.; that is, all meshes use the same time step.
Original issue reported on code.google.com by mcgratta
on 2015-05-29 12:58:31
read.f90
TAU_PART= 0._EB
->
TAU_PART=1.0_EB (by User's Guide)
Original issue reported on code.google.com by springcb38
on 2015-06-15 02:32:32
hvac.f90
SUBROUTINE SET_HVAC_DEFAULTS
:
COOLANT_TEMPERATURE = 293.15_EB
->
COOLANT_TEMPERATURE = 0._EB
Original issue reported on code.google.com by springcb38
on 2015-06-15 04:22:11
->
COOLANT_TEMPERATURE = 20._EB
Original issue reported on code.google.com by springcb38
on 2015-06-15 04:23:31
fixed coolant temperature.
Original issue reported on code.google.com by drjfloyd
on 2015-06-15 13:36:01
what about #92 ?
Original issue reported on code.google.com by springcb38
on 2015-06-16 00:11:47
Kevin,
Any reason we have TAU_PART=0 in the source? Should we change the source or the guide
for this one?
Jason
Original issue reported on code.google.com by drjfloyd
on 2015-06-16 17:48:29
My guess is that we set it to zero to satisfy some verification case. I would set it
to 1 in the source, just to be consistent with other ramped quantities.
Original issue reported on code.google.com by mcgratta
on 2015-06-16 18:29:17
changed TAU_PART to 1.
Original issue reported on code.google.com by drjfloyd
on 2015-06-17 12:20:25
<source code>
OUTPUT_QUANTITY(161)%NAME = 'ASPIRATION'
OUTPUT_QUANTITY(161)%UNITS = '%/m'
<User guide>
ASPIRATION Section 15.3.7 %
->
ASPIRATION Section 15.3.7 %/m
Original issue reported on code.google.com by springcb38
on 2015-06-18 01:15:11
<User guide>
FRICTION VELOCITY Section 16.10.14 B,D
->
FRICTION VELOCITY Section 16.10.14 m/s B,D
Original issue reported on code.google.com by springcb38
on 2015-06-18 01:25:47
Original issue reported on code.google.com by
springcb38
on 2013-03-11 14:02:58