msi: guard duplicated instance (not adding a new option) #648

Closed daipom closed 1 week ago

daipom commented 1 week ago

Abstraction

Spec change

Before:

We can launch Fluentd by fluentd.bat even though fluentdwinsvc is running. Launching multiple Fluentd with the same config may cause inconsistency of the buffers or the pos files.

After:

We can't launch Fluentd by fluent.bat with the default config path if fluentdwinsvc is running. If one of the following options is specified, we can execute fluentd.bat as before.

Output

When the fluentdwinsvc is running, the behavior of fluentd.bat is as follows:

> fluentd
Error: Can't start duplicate Fluentd instance with the default config.

To start Fluentd, please do one of the following:
  (Caution: Please be careful not to start multiple instances with the same config.)
  - Stop the Fluentd Windows service 'fluentdwinsvc'.
  - Specify the config path explicitly by '-c' ('--config').

> fluentd -v
Error: Can't start duplicate Fluentd instance with the default config.

To take the version, please use '--version', not '-v' ('--verbose').

To start Fluentd, please do one of the following:
  (Caution: Please be careful not to start multiple instances with the same config.)
  - Stop the Fluentd Windows service 'fluentdwinsvc'.
  - Specify the config path explicitly by '-c' ('--config')
daipom commented 1 week ago

The msi installer is broken. I'm checking the cause.

daipom commented 1 week ago

Why is fluentdwinsvc service running during the installation?? The installer may not be behaving correctly in the first place. => This is no problem. StartServices action looks unnecessary, but it is harmless because the service is not registered at that point.

However, #622 does not have this problem. I wander what the difference is. => delayed expansion: https://github.com/fluent/fluent-package-builder/pull/648#discussion_r1654227872

msi.log

...
Action start 15:02:23: WriteEnvironmentStrings.
WriteEnvironmentStrings: Name: Updating environment strings, Value: , Action 
Action ended 15:02:23: WriteEnvironmentStrings. Return value 1.
Action 15:02:23: StartServices. Starting services
Action start 15:02:23: StartServices.
Action ended 15:02:23: StartServices. Return value 1.
Action 15:02:23: RegisterUser. Registering user
Action start 15:02:23: RegisterUser.
Action ended 15:02:23: RegisterUser. Return value 1.
Action 15:02:23: RegisterProduct. Registering product
Action start 15:02:23: RegisterProduct.
RegisterProduct: Registering product
Action ended 15:02:23: RegisterProduct. Return value 1.
Action 15:02:23: PublishFeatures. Publishing Product Features
Action start 15:02:23: PublishFeatures.
PublishFeatures: Feature: Publishing Product Features
Action ended 15:02:23: PublishFeatures. Return value 1.
Action 15:02:23: PublishProduct. Publishing product information
Action start 15:02:23: PublishProduct.
PublishProduct: 
Action ended 15:02:23: PublishProduct. Return value 1.
Action 15:02:23: SetCreateCompatTdAgentBat. 
Action start 15:02:23: SetCreateCompatTdAgentBat.
Action ended 15:02:23: SetCreateCompatTdAgentBat. Return value 1.
Action 15:02:23: CreateCompatTdAgentBat. 
Action start 15:02:23: CreateCompatTdAgentBat.
CreateCompatTdAgentBat: 
Action ended 15:02:23: CreateCompatTdAgentBat. Return value 1.
Action 15:02:23: SetCreateCompatTdAgentGemBat. 
Action start 15:02:23: SetCreateCompatTdAgentGemBat.
Action ended 15:02:23: SetCreateCompatTdAgentGemBat. Return value 1.
Action 15:02:23: CreateCompatTdAgentGemBat. 
Action start 15:02:23: CreateCompatTdAgentGemBat.
CreateCompatTdAgentGemBat: 
Action ended 15:02:23: CreateCompatTdAgentGemBat. Return value 1.
Action 15:02:23: InstallFinalize. 
Action start 15:02:23: InstallFinalize.
Action 15:02:23: ProcessComponents. Updating component registration
Action 15:02:27: CreateFolders. Creating folders
CreateFolders: Folder: C:\opt\fluent\
Action 15:02:27: InstallFiles. Copying new files
Action 15:02:44: InstallFluentdWinSvc. 
WixQuietExec64:  Error: Can't start duplicate Fluentd instance with the default config.
WixQuietExec64:  
WixQuietExec64:  To start Fluentd, please do one of the following:
WixQuietExec64:    (Caution: Please be careful not to start multiple instances with the same config.)
WixQuietExec64:    - Stop the Fluentd Windows service 'fluentdwinsvc'.
WixQuietExec64:    - Specify the config path explicitly by '-c' ('--config').
WixQuietExec64:  Error 0x80070002: Command line returned an error.
WixQuietExec64:  Error 0x80070002: QuietExec64 Failed
WixQuietExec64:  Error 0x80070002: Failed in ExecCommon method
CustomAction InstallFluentdWinSvc returned actual error code 1603 (note this may not be 100% accurate if translation happened inside sandbox)
Action ended 15:02:44: InstallFinalize. Return value 3.
Action 15:02:44: Rollback. Rolling back action:
Rollback: InstallFluentdWinSvc
...
daipom commented 1 week ago

The msi installer is broken. I'm checking the cause.

This problem is resolved. However, some test problems remains. I'm fixing them. => Fixed.

kenhys commented 1 week ago

This approach may be better than #622.

daipom commented 1 week ago

Rebased to #647 as #647 got some changes.

daipom commented 1 week ago

This approach may be better than #622.

Thanks for considering. If we need a force execution option or a strict check whether the config path is the same in the future, let's revive #622!

kenhys commented 1 week ago

As #647 was merged into master, let's rebase with it.

daipom commented 1 week ago

As #647 was merged into master, let's rebase with it.

Done!

kenhys commented 1 week ago

Let's merge when all ci has passed.

daipom commented 1 week ago

Thanks for your review!

daipom commented 1 week ago

Can we put this in v5.0.4?

kenhys commented 1 week ago

Can we put this in v5.0.4?

This should be released in v5.0.4 IMHO.

daipom commented 1 week ago

Refactored the variable name NEED_DUPLICATE_LAUNCH_CHECK -> PREVENT_DUPLICATE_LAUNCH