Closed GoogleCodeExporter closed 9 years ago
Also, I calculated the DVH with dicompyler, and it could calulate the volumes
of the other structures without the indexerror.
Thanks
Original comment by landon.d...@gmail.com
on 28 May 2011 at 5:17
A few questions for you.
1) Which TPS did you use to generate the DICOM files?
2) Is the Rx dose (2200 cGy) correct?
Roy
Original comment by roy.coding@gmail.com
on 28 May 2011 at 5:21
Eclipse 8.2. Yes, single fraction stereotactic treatment. Couch rails were
added to the dataset within Eclipse for dose calculation.
Original comment by landon.d...@gmail.com
on 28 May 2011 at 5:27
I ran through the export again and saw what I probably did wrong. I selected
field dose rather than total dose, so it exported individual dose files rather
than the composite.
Thanks
Original comment by landon.d...@gmail.com
on 28 May 2011 at 6:41
Hi Landon,
Glad you figured it out. The max dose is calculated from the max value of the
dose grid. If the shown field only contributes 33% of the dose to the Rx, then
that would explain why you see the number.
Also, when you were on the import screen, did you see multiple dose files
listed under the RT Plan object? If so, this would be similar to Issue 14, and
we need to sum the dose files into one dose grid for composite beam display.
Is it possible for you to anonymize and send a copy of the exported field dose
data (along with the CTs and plan)? We would like to support as many possible
variations of DICOM data within dicompyler.
Thanks,
Adit
Original comment by bastula
on 28 May 2011 at 2:31
Original comment by bastula
on 19 May 2012 at 10:04
This issue was closed by revision e57a18e35d8e.
Original comment by bastula
on 19 May 2012 at 3:59
Original issue reported on code.google.com by
landon.d...@gmail.com
on 28 May 2011 at 5:12Attachments: