I met the same problem when using Acpype with old version of Antechamber
(AmberTools12). And I have come up a workaround that works for me.
Based on the discussion in
https://code.google.com/p/acpype/issues/detail?id=16, 2nd WARNING: "Setting
mopac for antechamber" means Acpype are looking for mopac instead of sqm for
the atomic partial charge calculation. However, mopac is non-existing in
AmberTool, therefore causing the problem.
My workaround is adding partial charge calculation option (-c) when executing
acpype (i.e. ./acpype.py -i input.mol2 -c user), which will overlook the step
of looking for default partial charge calculation program, so process the rest.
You can alway use other more sophisticated methods to obtain the atomic partial
charge such as RESP fitting and such.