Bottom symbols get chopped of when connecting a PAL Video camera. #5

Closed GoogleCodeExporter closed 8 years ago

GoogleCodeExporter commented 8 years ago
What steps will reproduce the problem?
1. Connect no camera, display should be correct
2. Reboot with PAL camera connected, bottom symbols should be cut off.
3.

What is the expected output? What do you see instead?

Expected symbols to be in the same positions when camera is connected.

What version of the product are you using? On what operating system?
MinimOSD V0.1

Please provide any additional information below.

Original issue reported on code.google.com by andre.lochner@gmail.com on 28 Jan 2012 at 8:52

GoogleCodeExporter commented 8 years ago
The Max7456 will create the video sync signal if there is no sync input 
(camera) connected. This explains the difference. If the camera is indeed PAL, 
then what is probably needed is the ability to adjust the border offsets to 
cope with that particular camera/video goggle combination. As the number of 
fields shown is perculiar to the camera etc, then this will need to be 
configurable by the user. 

Original comment by mandro...@googlemail.com on 9 Feb 2012 at 12:18

GoogleCodeExporter commented 8 years ago
Please, notice that now you can use ArduCAM OSD Config tool to fit the layout 
better to any particular cases. ;)