Closed vio2000 closed 4 years ago
HI @vio2000,
most of the Eltako actuator cannot be auto discovered except Eltako sensors. You first have to define a rollershutter thing manually:
As these actuators do not send an absolute position you have to set up the shut time (time it needs to close the rollershutter) in the rollershutter channel.
Hi @fruggy83 thank you. It's working now.
Glad to hear that it works now 👍
Hi @fruggy83, another problem occurs. I bought a Eltako TF61J-230V Unfortunately, I can't find it in the inbox. In the log, I get the following errors: 2020-01-09 20:44:53.476 [INFO ] [covery.EnOceanDeviceDiscoveryService] - Stopping EnOcean discovery scan
2020-01-09 20:44:53.478 [INFO ] [covery.EnOceanDeviceDiscoveryService] - Starting EnOcean discovery and accepting teach in requests
2020-01-09 20:45:11.210 [DEBUG] [ernal.transceiver.EnOceanTransceiver] - RADIO_ERP1 with RORG MSC for payload D100D0FF000004360589AE460100FFFFFFFF4900 received
2020-01-09 20:45:11.212 [ERROR] [ernal.transceiver.EnOceanTransceiver] - Exception in informListeners
2020-01-09 20:45:11.730 [DEBUG] [ernal.transceiver.EnOceanTransceiver] - RADIO_ERP1 with RORG MSC for payload D100D0FE03030100740589AE460000FFFFFFFF4900 received
2020-01-09 20:45:11.732 [ERROR] [ernal.transceiver.EnOceanTransceiver] - Exception in informListeners
2020-01-09 20:45:53.478 [INFO ] [covery.EnOceanDeviceDiscoveryService] - Stopping EnOcean discovery scan
Even if I attach the Rollershutter manually, it doesn't work at all. Do you have any hint/advice for me?