What steps will reproduce the problem?
1. Compare 2000 & 2005 Database objects
What is the expected output? What do you see instead?
It should show the diff.
Error:
'SCHEMA_NAME' is not a recognized function name.
at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection)
at System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection)
at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj)
at System.Data.SqlClient.TdsParser.Run(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj)
at System.Data.SqlClient.SqlDataReader.ConsumeMetaData()
at System.Data.SqlClient.SqlDataReader.get_MetaData()
at System.Data.SqlClient.SqlCommand.FinishExecuteReader(SqlDataReader ds, RunBehavior runBehavior, String resetOptionsString)
at System.Data.SqlClient.SqlCommand.RunExecuteReaderTds(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, Boolean async)
at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method, DbAsyncResult result)
at System.Data.SqlClient.SqlCommand.RunExecuteReader(CommandBehavior cmdBehavior, RunBehavior runBehavior, Boolean returnStream, String method)
at System.Data.SqlClient.SqlCommand.ExecuteReader(CommandBehavior behavior, String method)
at System.Data.SqlClient.SqlCommand.ExecuteReader()
at DBDiff.Schema.SQLServer.Generates.Generates.GenerateRules.Fill(Database database, String connectionString)
at DBDiff.Schema.SQLServer.Generates.Generates.Generate.Process()
at DBDiff.Front.ProgressForm.ProgressForm_Activated(Object sender, EventArgs e)
at System.Windows.Forms.Form.OnActivated(EventArgs e)
at System.Windows.Forms.Form.set_Active(Boolean value)
at System.Windows.Forms.Form.WmActivate(Message& m)
at System.Windows.Forms.Form.WndProc(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)
at System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)
at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
What version of the product are you using? On what operating system?
V0.4.0.0 & Windows 2003
Please provide any additional information below.
Program is executed on WinXP
Original issue reported on code.google.com by Kailas.S...@gmail.com on 14 Jul 2010 at 3:01
Original issue reported on code.google.com by
Kailas.S...@gmail.com
on 14 Jul 2010 at 3:01